2
Internal EEPROM memory
The DIN module automatically stores the measured water temperature into internal memory
–
3x daily at pre-set
times:
10:00 / 16:00 / 22:00
.
Other features and protective functions
Heating priority
–
system will automatically switch on the filtration pump for 5 mins each hour to check the water
temperature. Based on the water temperature settings the filtration pump may be switched on for heating or cooling.
Can be deactivated with a DIP switch.
Anti-freeze protection
–
with water temperature below 4°C the system will automatically run the filtration pump
every ½ hour in order to keep the water from freezing.
Salinator protection
–
with water temperature below 14°C the system will automatically deact
ivate the R2 relay
output (Dosing/Atr2) to prevent the salinator from operating in cold water.
1.
Safety instructions
Read this user manual before installation and unit activation
. Should you need any explanation or should you
have any doubts, do not hesitate to contact Your VArio supplier.
If you use any personal electronic medical device (peacemaker, etc.),
please consult the device manufacturer
concerning potential radio interference which may affect the medical device. VArio system modules use radio
communication on 869,530 MHz with peak output ≤ 20mW.
The unit shall be always installed by a trained professional. Always disconnect the main power supply before
performing repairs or maintenance, or before connecting additional external devices.
The DIN module must always be powered from the safety-protected power source of filtration or
recirculation pump.
The system uses radio-frequency communication. It is forbidden to use the device near mines / quarries
or any places with possible risk of explosion.
2.
General information
Pool control system consists of a VA RIO DIN module, which can control up to 5 output relays
(filtering, dosing, lights, heating, attraction), and a local radio remote control unit VA RIO RC
(furthermore RC module). The relay outputs are pre-set from the factory as follows:
DIN module
R1
–
Filtration (4 programmable timers - programs)
R2
–
Dosing (operation depends on filtering time - 25%/50%/75%/100% of filtering time) / Attraction2 (timer)
R3
–
Lights (timer - 15 min. step: 0/15/30/45/60/90/120/180/240 min. or permanent ON)
R4
–
Heating (heating or cooling based on the pre-set/actual temperature)
R5
–
Attraction (timer - 15 min. step: 0/15/30/45/60/75/90/105/120 min)
RC module
provides information and statuses of relay contacts and outputs and allow the user
to modify the parameters. When a dosing station is connected (VA DOS EXACT / VA DOS BASIC
/ VA DOS FLOC / VA FOR SALT pH), the RC will display actual water quality parameters as
measured by the dosing unit and will also allow the user to change the operating parameters
of the dosing unit.
3.
Technical information
DIN module (VArio)
Dimensions (w
–
h
–
d)
Material
Flammability Class
Power supply/consumption
Temperature sensor:
Output relays:
Frequency / Band
106,3 x 57,8 x 90,2 mm
ABS nylon 66
UL94V-066
100-250 VAC 50-60 Hz / max. 12W
0 - 50
°C
(
±0
,
5 °
C)
8 A 250 V (potential-free contact)
869,530 / P, max. output
≤ 20mW
RC module (VA RIO RC)
Dimensions (w
–
h
–
d)
Material
Power supply
Frequency / Band
81 x 165 x 31 mm
ABS
4,5V, 3x AA (rechargeable batteries may be used)
869,530 / P, max. power
≤ 20mW
Содержание VArio DIN module
Страница 1: ...1 20 02_ver 1 11_VA SYST M ZEN BAZ NOV TECHNOLOGIE RC modul d lkov ovl d n CZ EN DE HR...
Страница 17: ...19 08_ver 1 11_VA POOL TECHNOLOGY CONTROL SYSTEM RC Module remote control...
Страница 33: ...1 19 08_ver 1 11 SCHWIMMBADTECHNIK STEUERANLAGE RC Modul Fernbedienung...
Страница 49: ...1 19 08_ver 1 11_VA SUSTAV UPRAVLJANJA BAZENSKOM TEHNOLOGIJOM RC modul daljinsko upravljanje...