background image

 

 

 

INSTALLATION, OPERATION and 

MAINTENANCE  

Figure 905 Air Release Valves 

 
 

INTRODUCTION 

This  manual  will  provide  the  information  to 
properly  install,  operate  and  maintain  the  valve 
to ensure a long service life.  The Figure 905 Air 
Release  Valve  is  ruggedly  constructed  to 
provide  years  of  trouble-free  operation  with 
minimal maintenance.  
 
These  Air  Release  Valves  are  not  intended  for 
use with fluids containing suspended solids such 
as  wastewater and  sewage.   The  GA  Industries 
Figure  925,  927  or  929  Air  Release  Valves  are 
recommended for such applications. 

 

CAUTION 

The  valve  is  NOT  recommended  for  use  with 
toxic  fluids,  fuels  or  fluids  containing  hazardous 
gases 
 

CAUTION 

The  valve  will not  function  if  used  at  a  pressure 
higher  than  the  maximum  working  pressure 
indicated on the nameplate. 
 
The  Shop  Order  (SO)  Number,  Figure  Number, 
size  and  pressure  rating  are  stamped  on  a 
nameplate attached to the valve.  Please refer to 
the SO number when ordering parts.  
 

DESCRIPTION OF OPERATION

 

The Figure 905 Air Release Valve is designed to 
automatically  vent  air  that  has  accumulated 
within  the  valve.    These  valves  are  usually 
installed  at  high  points  in  the  system  where  air 
tends to collect.  The valve 

is “normally open” as 

shipped and will vent air through its orifice at the 
top  of  the  valve.    The  float  rises  when  water 
enters the valve and closes the orifice.  Air from 
the system accumulates in the valve forcing the 
water level down until the float drops and opens 
the  venting  orifice.    As  air  is  released the  water 
level  rises  lifting  the  float  and  re-closing  the 
valve.  
 
This  sequence  occurs  as  often  as  necessary  to 
release air that has collected in the valve. 
 

 
 
RECEIVING AND STORAGE 

Inspect  the  valve  upon  receipt  for  damage 
during  shipment.    Carefully  unload  all  valves  to 
the ground without dropping.   
 
The  valves  should  remain  in  a  clean,  dry  and 
weather  protected  area  until  installed.    For  long 
term storage (greater than 6 months) the rubber 
surfaces  of  the  seat  should  be  coated  with  a 
non-toxic  lubricant  such  as  "SuperLube"  made 
by  Synco  Chemical.    Do  not  expose  the  rubber 
parts to sunlight or ozone. 
 

INSTALLATION 

The  Figure  905  is  standard  with  NPT  screwed 
connections.    Consult  the  drawings  of  record  to 
verify the configuration supplied and installed. 
 
The valve must be installed in an upright vertical 
orientation,  normally  at  a  high  point  in  the 
system. 
 
If  installed  outdoors,  below  ground  in  a  vault  or 
in an unheated area, adequate freeze protection 
must  be  provided.    Some  discharge  of  water 
may  occur  during  operation  so  the  valve  outlet 
should be piped to an adequate drain. 
 
An  isolating  valve  should  be  installed  between 
the valve and the pipeline or system to facilitate 
maintenance.    
 
Carefully  screw  threaded  end  valves  onto  pipe 
nipple using compatible thread sealant.  Tighten 
valve  using  wrench  flats.    DO  NOT  OVER-
TIGHTEN. 
 

VALVE CONSTRUCTION 

The standard Figure 905 Air Release Valve has 
a cast iron body, stainless steel float and linkage 
mechanism and a rubber seat and is suitable for 
use at working pressures from 10 to 150 PSI (69 
to  1,034  k

Pa).  If there is an “H” suffixed to the 

figure  number  (e.g.,  905H)  the  valve  is  suitable 
for  use  at  up  to  200  PSI  (1,379  kPa)  working 
pressure.    Refer  to  the  List  of  Materials 

Содержание GA INDUSTRIES 983-D

Страница 1: ...Combination Air Valves with Surge Check Instructions SECTION 2 Figure 930 Air Vacuum Valve Instructions SECTION 3 Figure 905 Air Release Valve Instructions SECTION 4 Figure F284 D Surge Check Instructions 234 Clay Avenue Mars PA 16046 USA Telephone 724 776 1020 Fax 724 776 1254 E mail info ga vag group com Manual Number IOM 983 01 3 4inch 082622 ...

Страница 2: ...Section 1 ...

Страница 3: ...Description of Operation 1 Receiving Storage 1 Installation 1 Start Up 2 Preventative Maintenance 2 Testing 2 Trouble Shooting 2 Repair Instructions 2 Replacement Parts 2 Warranty 2 Assembly Drawing Component Location 2 234 Clay Avenue Mars PA 16046 USA Telephone 724 776 1020 Fax 724 776 1254 E mail info ga vag group com Manual Number IOM 983 01 3 4 082622 ...

Страница 4: ...d all valves to the ground without dropping Valves should remain in a clean dry and weather protected area until installed After completion of shop testing the valve is drained of the test water but a small residual amount could remain so the valve should be protected from freezing during storage INSTALLATION Figure Number 983 D has an ANSI Class 125 flanged pipeline connection The standard valve ...

Страница 5: ...slowly open the isolating valve 6 The Figure 930 float should rise and seal tightly while the Figure 905 may continue to release air for a while then close tightly TROUBLESHOOTING SYMPTOM or PROBLEM SOLUTION Leakage from outlet of Air Vacuum valve when closed Debris lodged between float and seat Remove debris inspect for damage Worn or damaged seat ring Inspect replace See Figure 930 Repair Instru...

Страница 6: ...Section 2 ...

Страница 7: ...ANUAL Figures 930 T 930 DT 930 UT to 4 Air Vacuum Valves for Clean Water Drawings EAV 7051 EAV 7052 EAV 7053 234 Clay Avenue Mars PA 16046 USA Telephone 724 776 1020 Fax 724 776 1254 E mail info ga vag group com Manual Number 931 1 IOM 082622 ...

Страница 8: ...all valves to the ground without dropping Do not pick up the valve by the cowl The valves should remain in a clean dry and weather protected area until installed For long term storage greater than 6 months the rubber surfaces of the seat should be coated with a non toxic lubricant such as SuperLube made by Synco Chemical Do not expose the rubber parts to sunlight or ozone INSTALLATION Sizes to 3 F...

Страница 9: ...nd to verify there is no fluid leakage TESTING Valve operation can be easily tested Close the inlet isolation valve and remove or loosen the pipe plug nearest the inlet to drain the water from the valve The float should drop as the water leaves the valve NOTE A ball or gate valve can be installed in place of the pipe plug to facilitate testing Replace or tighten the pipe plug and slowly open the i...

Страница 10: ...lated 5 Float Ball 316 Stainless Steel 6 Pipe Plug Malleable Iron 7 Cover Nuts Steel Zinc Plated 8 Float Guide 3 UHMW Polyethylene 4 Stainless Steel 9 Cushion Buna N Rubber 10 Bearing Acetal Polymer 11 Pipe Nipple Brass 12 Flange Cast Iron Figure 1 Standard NPT Inlet Parts 11 12 Only on Optional Flanged Inlet REPLACEMENT PARTS Genuine replacement parts are available from your local VAG GA Industri...

Страница 11: ...Section 3 ...

Страница 12: ...TION OPERATION AND MAINTENANCE MANUAL Figure 905 1 Air Release Valves Drawing EAV 7010 234 Clay Avenue Mars PA 16046 USA Telephone 724 776 1020 Fax 724 776 1254 E mail info ga vag group com 905 IOM 022620 Rev B ...

Страница 13: ...r level rises lifting the float and re closing the valve This sequence occurs as often as necessary to release air that has collected in the valve RECEIVING AND STORAGE Inspect the valve upon receipt for damage during shipment Carefully unload all valves to the ground without dropping The valves should remain in a clean dry and weather protected area until installed For long term storage greater t...

Страница 14: ...e is not preventing the float from freely falling when fluid is drained from valve Verify linkage mechanism operates freely without binding or sticking Verify pressure at valve inlet does not exceed maximum working pressure DISASSEMBLY Although the Figure 905 air release valve may be more easily serviced by removing it from the line all valves can be serviced while the body remains connected to th...

Страница 15: ...ax 724 776 1254 E mail quotes ga vag group com Please have the nameplate data available when ordering parts REPAIR KITS Soft Goods Kit A905 Part Number 2 80 11000 002 includes items 3 and 7 Linkage Kit AL905 Part Number 2 80 11000 078 includes items 5 6 8 and 14 WARRANTY The Warranty for GA Industries valves is included in our Terms and Conditions which can be found here https gaindustries com ter...

Страница 16: ...Section 4 ...

Страница 17: ...TALLATION OPERATION AND MAINTENANCE MANUAL Figure F284 D Anti Slam Surge Check Valves 234 Clay Avenue Mars PA 16046 USA Telephone 724 776 1020 Fax 724 776 1254 E mail info ga vag group com IOM F284D 070822 ...

Страница 18: ...ould remain in a clean dry and weather protected area until installed For long term storage greater than 6 months the rubber surfaces of the seat should be coated with a non toxic lubricant such as SuperLube made by Synco Chemical Do not expose the rubber parts to sunlight or ozone VALVE CONSTRUCTION GA Industries Figure F284 D Anti slam Surge Check Valves have a globe style valve body with integr...

Страница 19: ...ocks or 2 x 4 s under the flange outboard of the bronze seat so that it can drop out of the body Ensure the surface beneath the valve will not damage the internal components when they drop out of the valve Place a metal rod on top of the stem inside the bushing Hit the top of the rod with a hammer or mallet and the internal components should drop out of the valve body Inspect the seating surfaces ...

Страница 20: ...meplate data available when ordering parts WARRANTY The Warranty for GA Industries valves is included in our Terms and Conditions which can be found here https gaindustries com terms Anti Slam Surge Check Valve Item Description Standard Material 1 Body Ductile Iron 2 Seat Lead Free Bronze 3 Poppet Lead Free Bronze 4 Seat O Ring EPDM Rubber 5 Seal EPDM Rubber 6 Bushing Bronze Table 1 Butterfly Valv...

Отзывы: