32
传感器范围设定与控制器输出不匹配
检查电流信号及设定
Fuel is not pure, well mixed liquid
(see chapter 6)
燃油不纯,混有其它液体
(
参见第
6
章
)
None
无
Sensor is damaged or fouled
探头损坏或污秽
Clean and inspect the sensor
(see chapter 8)
检查并清洗
(
参
见第
8
章
)
Viscosity output is max
range
黏度输出为设定最大
The viscosity in the sensor housing is
higher than the max range
探头仓室中黏度高于最大设定值
Heat up the fluid
加热
Actual viscosity is higher than
expected.
E.g. bunker calculator only gives
approx. value.
实际黏度高于预期
None
无
ViscoSense
®
2 interface box is
malfunctioning
界面盒发生故障
Check diagnostic led
检查诊断二极管
ViscoSense
®
2 sensor is
malfunctioning
探头发生故障
Range settings ViscoSense
®
2 and
readout unit do not match
传感器设置与控制器输出不匹配
Check mA signal and range
settings
检查电流信号及设置
Sensor is damaged or fouled
探头损坏或赃污
Clean and inspect the sensor
(see chapter 8)
检查并清洗
(
参见第
8
章
)