Setup 

The standard setup consists of a ControlVIEW Xtreme and one, two, three, or 
four VISCA compatible PTZ cameras and an external triggering device.  In this 
configuration, the system will provide up to four cameras with total of 72 preset 
positions.  Any preset can be stored to any camera.

 

 

 

 1.

 

Connect the 

Camera

 port of the ControlVIEW Xtreme to the RS-232 input 

of the first camera.  If more cameras are to be used connect them together 
in a daisy chain by connecting RS-232 out of Camera One to RS-232 In of 
camera two.  Repeat for additional cameras. 

2.

 

When applicable, connect the 

Control 

port on the ControlVIEW Xtreme to 

an available serial port on a control system (i.e., Crestron, AMX). 

3.

 

Connect a wire between the port labeled 

Ground

 on the ControlVIEW 

Xtreme and a ground port on any/all external triggering devices (i.e. 
MicVIEW, TouchVIEW, AutoVIEW). 

4.

 

Connect the contact closure output pins or the voltage activated output 
pins of the triggering device to the 

Preset Input

 pins of the ControlVIEW 

Xtreme.  (See Appendix B for Pinout diagram for ControlVIEW Xtreme). 

5.

 

Using an S-video cable, connect the video output from camera one to the 
video input for camera one on the ControlVIEW Xtreme.  Repeat this step 
for additional cameras where necessary.  

 

Note:  The ControlVIEW Xtreme ONLY supports S-Video input.  For people 
with other needs, there is an external video switch controller.  See Appendix B for 
pin out. 
 

6.

 

Connect the S-Video and/or Composite Video out on the ControlVIEW 
Xtreme to the video input on a display device (i.e. monitor, CODEC, or 
AV distribution).  

 
Note:  The ControlVIEW Xtreme outputs BOTH S-Video and composite video 
simultaneously.   
 

7.

 

Power up all cameras. 

 
Note:  If any of the cameras become disconnected from the daisy-chain or lose 
power, it will be necessary to reset the ControlVIEW Xtreme to re-establish the 
camera link. Presets will NOT be lost since presets are stored in non-volatile 
memory on the ControlVIEW Xtreme. 

 
8.

 

Power up any/all external triggering devices (MicVIEW, AutoVIEW, 
TouchVIEW, etc.) 

9.

 

Make sure all external triggering systems are not attempting to trigger the 
ControlVIEW Xtreme. 

10.

 

Power up the ControlVIEW Xtreme. 

 
Note:  All triggering devices must be idle and not attempting to trigger the 

Содержание ControlVIEW Xtreme

Страница 1: ...ers Unpacking the ControlVIEW Xtreme Carefully remove the device and part of the packing material Set the unit on a flat solid surface unpack and identify the following parts One Power Supply One Powe...

Страница 2: ...deo Output to display distribution system 8 Switcher Control Output for Controlling External Video Switcher 9 RS 232 output Serial Connection to Camera s 10 RS 232 input Serial Connection from Control...

Страница 3: ...Appendix B for Pinout diagram for ControlVIEW Xtreme 5 Using an S video cable connect the video output from camera one to the video input for camera one on the ControlVIEW Xtreme Repeat this step for...

Страница 4: ...t moving it The Camera default setting is also a separate option to choose which camera will be selected It is recommended to set the Default Timer when setting the Default Preset Default Timer This s...

Страница 5: ...the arrow points to Tilt Speed 2 Press Select 3 Press Up or Down arrow to point to the speed desired Higher numbers are faster 4 Press Select Note The Tilt Speed only affects the speed of moving from...

Страница 6: ...be connected to the Joystick and the DB25 port for presets 49 72 1 Using the Menu Control buttons Press UP or DOWN until the arrow points to Jstik Priority 2 Press Select 3 Press Up or Down arrow to p...

Страница 7: ...s even when the system and cameras are off The system may be safely powered down using the enclosed remote or by simply disconnecting power Control system users For users with an external control syst...

Страница 8: ...me Confirm this serial port on the control device is set to 9600 bps 8N1 no parity and no flow control Check all serial connections to the camera Confirm that serial port on the ControlVIEW Xtreme is...

Страница 9: ...is between 1 and 72 KEYPAD XX Allows the Control System to activate or reactivate the keyboard on the front panel of the ControlVIEW Xtreme XX ON or OFF RESET Resets the ControlVIEW Xtreme while remem...

Страница 10: ...set information Directs the ControlVIEW Xtreme to send the menu shown above to host PASS Sending the PASS instruction followed by a CR then followed by a camera instruction passes the camera instructi...

Страница 11: ...Appendix B ControlVIEW Xtreme Port Pin Configuration Rear view of ControlVIEW Xtreme Presets 25 48 Preset 25 Preset 37 GND Preset 38 Preset 48 Preset 49 Preset 61 GND Preset 62 Preset 72 Presets 49 72...

Страница 12: ...inside Keep this device away from food and liquid To clean the exterior wipe with a damp cloth Do not use abrasive chemicals Operating in storage conditions Do not store or operate this device under...

Страница 13: ...a product for repair or replacement request an RMA from Vaddio s technical support Provide a technician with a return phone number e mail address shipping address and product serial numbers Describe...

Отзывы: