Camera Switch Settings (rotary and dip switches): 

The CeilingVIEW HD-18 DocCAM has a 16-position rotary switch to select HD camera resolutions or three (3) of 
the  most  used  RGBHV  resolutions  today.    The  camera  also  has  an  8-position  dip  switch  for  assigning  certain 
camera functions.  The following Label appears on the back of the camera enclosure back box: 
 
 
  
 
 
 
 
 
 

 
 
 

 
 
 
 
 
Dip Switch Settings Table: 

SW  Function 

Default 

Description/Notes 

IR ON/OFF 

ON 

Allows IR remotes to control the camera,  
Turn IR off if using RS-232 for camera control 

Baud Rate 

9600 bps 

9600 bps works well with Vaddio equipment, especially over distance 

Alternate IR 
Remote 

OFF 

Turn ON to use zoom in/out controls with Polycom®, LifeSize® or 
Cisco®/TANDBERG IR remote controls.  The tilt down command on 
these remotes will activate the momentary laser pointer for document 
positioning. 

Laser Pointer 

ON 

Allows the Laser Pointer to be controlled by IR remote or RS-232 
when ON, Turn OFF if the Laser Pointer is not used 

Test Bars 

OFF 

Convenience, Non-standard Color Bars Only 

Not Used 

OFF 

Leave OFF 

Not Used 

OFF 

Leave OFF 

Not Used 

OFF 

Leave OFF 

 
 
Video Select - Rotary Switch: 

Select the HD video resolution best suited to the application where the camera is 
installed.  The HSDS™ (differential) video is routed to the Quick-Connect SR or 
the Quick-Connect DVI/HDMI Interfaces over a Cat-5e cable.  The DE-15 (15pin-
HD) connector will also output the analog YPbPr signal on the back of the back 
box enclosure. 
 
The  three  (3)  most  popular  RGBHV  resolutions  are  also  included,  selecting 
positions 9, E or F will override the YPbPr output and that output will no longer 
function.  RGBHV in 1024x768@60Hz, 1280x800@60Hz and 1680x1050@60Hz 
will be delivered out of the DE-15 on the back of the camera module only.  The 
Quick-Connect SR Interfaces will no longer output YPbPr or DVI/HDMI video. 
 
When the dip and rotary switches are set for the application, put the cover caps back on and proceed with the 
installation.    These  switches  are  accessible  from  the  front  of  the  camera  after  installation  and  can  be  easily 
changed. 

 

IR

ON

1

38400

bps

2

3

4

5

DIP SWITCH SETTINGS

9600

bps

1080p/60

B

3

7

6

5

4

1080p/50

1080i/50

720p/50

F

E

D

C

VIDEO SELECT

2

0

1080p/59.94

1

1080i/59.94

720p/59.94

A

9

8

1280 x 800/60 RGBHV

1680 x 1050/60 RGBHV

1024 x 768/60 RGBHV

ON

6

7

8

OFF

ON

8

7

OFF

IR

OFF

ALTERNATE

IR REMOTE

OFF

LASER

ON

OFF

TEST

BARS

OFF

6

OFF

1080p/30

1080p/25

Содержание 999-3018-000

Страница 1: ...AMERA VADDIO Model Numbers 999 3018 000 CeilingVIEW HD 18 DocCAM with Quick Connect SR Interface North America 999 3018 001 CeilingVIEW HD 18 DocCAM with Quick Connect SR Interface International 999 3...

Страница 2: ...CeilingVIEW HD 18 DocCAM Series CeilingVIEW HD 18 DocCAM Manual Document Number 342 0195 Rev B 2 of 24 Inside Front Cover Blank...

Страница 3: ...ng the device please read the entire manual thoroughly The system was designed built and tested for use indoors and with the provided power supply and cabling The use of a power supply other than the...

Страница 4: ...2 x Phillips Flat Head Screws for Trim Ring x One 1 Quick Connect SR Interface 998 1105 016 x One 1 Vaddio CeilingVIEW HD 18 DocCAM IR Remote Control x One 1 RJ 45 to RS 232 Control Adapter 998 1001 2...

Страница 5: ...or hardwood ceilings and includes mounting flanges a larger white trim ring and mounting hardware kit x Before starting the installation of the CeilingVIEW HD 18 DocCAM check above the ceiling where t...

Страница 6: ...ht of the camera into the grid to avoid tile warping The tile support brace also has 3 8 holes which can be used as support points to tie the camera to the structure in areas that have seismic mitigat...

Страница 7: ...eave OFF 7 Not Used OFF Leave OFF 8 Not Used OFF Leave OFF Video Select Rotary Switch Select the HD video resolution best suited to the application where the camera is installed The HSDS differential...

Страница 8: ...is possible to send IR from third party IR remote controls to third party equipment such as videoconferencing codecs IR can be output as either modulated for IR Probe or non modulated direct connectio...

Страница 9: ...DMI Transmitter HDMI v 1 3 with deep color and DVI v 1 0 Compliant use the Recessed Color Space Conversion Switch to toggle between YCbCr HDMI and sRGB RGBHV color spaces to suit your monitors 9 YPbPr...

Страница 10: ...ironments 5 Connector Label This label identifies the RS 232 RJ 45 jack EZCamera Power HD Video RJ 45 jack and the RGBHV connector The arrows also indicate the top of the image 6 Product Label Serial...

Страница 11: ...ing the holes along either side of the tile support brace Step 4 Connect the camera before placing it in the ceiling Two 2 Cat 5e cables are required for the CeilingVIEW HD 18 DocCAM to operate proper...

Страница 12: ...n RS 232 adapter 9 Pin to RJ 45 is included with the system Step 7 Connect the 24 VDC power supply s DC side to the power connector on the Quick Connect SR Interface and plug the high voltage side int...

Страница 13: ...IR Remote ON is down The Vaddio IR remote will continue to work unless dip switch 1 is set to OFF x In addition to the ZOOM commands the Polycom LifeSize and Cisco TANDBERG Tilt Down command activates...

Страница 14: ...pply 24 VDC 2 0 Amp PowerRite Power Supply with AC Cord Sets Origin Made in the USA Minneapolis St Paul Minnesota Quick Connect SR Systems Quick Connect DVI HDMI SR Interface and HD 18 Quick Connect S...

Страница 15: ...of 3rd party IR Remotes to control codecs Generally the main camera in a system may have the requirement for IR Forwarding but for added flexibility the CeilingVIEW HD 18 also can forward the IR comma...

Страница 16: ...r repairs or returns as well as the date of purchase and proof of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number on the outside of the box w...

Страница 17: ...ce This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications...

Страница 18: ...ratus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n emet pas de bruits radio lectriques d passant les limites applicables a...

Страница 19: ...om Position V Speed 0 7 CAM_Focus Stop Far Standard Near Standard Far Variable Near Variable AutoFocus ManualFocus Auto Manual 81 01 04 08 00 FF 81 01 04 08 02 FF 81 01 04 08 03 FF 81 01 04 08 2p FF 8...

Страница 20: ...f On Off 81 01 06 08 02 FF 81 01 06 08 03 FF 81 01 06 08 10 FF Preset Zoom Speed Zoom Speed 81 01 7E 01 0B 00 00 ZZ FF ZZ Zoom Speed 0 7 BLK Enhance Pedestal 81 01 7E 53 00 00 0p 0q FF pq Black Level...

Страница 21: ...Neg Art On B W On CAM_MemoryInq 81 09 04 3F FF y0 50 0p FF p Memory No 0 0xf CAM_IDInq 81 09 04 22 FF y0 50 0p 0q 0r 0s FF pqrs 0000 FFFF CAM_IR_ReceiveInq 81 09 06 08 FF y0 50 02 FF y0 50 03 FF On Of...

Страница 22: ...CeilingVIEW HD 18 DocCAM Series CeilingVIEW HD 18 DocCAM Manual Document Number 342 0195 Rev B 22 of 24 CeilingVIEW HD 18 DocCAM Notes...

Страница 23: ...CeilingVIEW HD 18 DocCAM Series CeilingVIEW HD 18 DocCAM Manual Document Number 342 0195 Rev B 23 of 24 Inside Back Cover Blank...

Страница 24: ...3 971 4464 www vaddio com 2011 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice Vadd...

Отзывы: