CeilingVIEW HD-18 DocCAM Connectors and Pin-out Detail:
The connections on the top of the camera enclosure are as follows:
1) One (1) RJ-45 connector for RS-232 communication and IR Out
2) One (1) RJ-45 connector for Power/Video to be connected to the Quick-Connect HD-18 SR or Quick-Connect
DVI/HDMI SR Interface.
x
RS-232/IR OUT RJ-45:
This jack provides for RS-232 bi-directional control and IR Out for IR Forwarding of 3
rd
party IR Remotes to
control codecs. Generally, the main camera in a system may have the requirement for IR Forwarding, but for
added flexibility, the CeilingVIEW HD-18 also can forward the IR commands from other IR Remotes (for
example Polycom, LifeSize and Cisco/TANDBERG C-Series codec remotes).
Pin
Function
1)
Unused
2)
Unused
3)
Unused
4)
IR Output (Diff Signal to Quick-Connect)
5)
IR Ground (Diff Signal to Quick-Connect)
6)
GND
7)
RXD (from TXD of control source)
8)
TXD (to RXD of control source)
x
Power/Video RJ-45:
The Power/Video Port supplies power to the CeilingVIEW HD-18 DocCAM and returns HSDS (differential HD
Video) up to 100’ (30.5m).
Pin
Function
1)
Power+
2)
Power-
3)
Y+
4)
PB+
5)
PB GND
6)
Y GND
7)
PR+
8)
PR-
12345678