background image

programming instructions

"Sealing" light will flash, the seal wire will work, and the LED display will begin 
to count backwards by 0.5 seconds. After "Sealing", it enters "Cooling" mode. 
The "Cooling" light will flash and the LED display will begin to count backwards 
by 0.5 second. After "Cooling", the releasing valve will function, and the  
operation will be completed.

10 .   "Vacuum Marinate" Mode

 - In "Vacuum Marinate" mode, close the lid and 

the "Marinate" light will flash. It takes nine minutes for a work cycle, including 
vacuuming, maintaining the vacuum, and releasing. After the work cycle, the 
machine enters the "Vacuum" machine mode (the same as #8), and the LED 
display will begin to count down. With 1 second to the end, the pump will stop 
working and the LED display will display the marinate time. The decimal point 
flashes and the countdown starts. After 8 minutes, the machine releases the air, 
starts the cycle, and continues to marinate until the marinate time countdown 
hits zero. At that point, the operation is completed. 

11 .   Cancel the Sealing/Cooling Operation

 - Press the "Stop" button to stop the  

operation and release the air while the machine is in the "Sealing/Cooling" mode.

12 .   Cancel the Gas/Sealing/Cooling Operation

 - Press the "Stop" button to stop the 

operation and release the air while the machine is in the "Gas/Sealing/Cooling" 
mode.

13 .   Machine Alarm Function

 - E01: When the machine enters the "Sealing"  

process, the vacuum lid is not closed for protection (the door control switch is 
not triggered to close); LP: When the machine is running, press the "Stop"  
button to exit and release.

14 .   Memory  Function

 - The machine will remember the last parameter setting  

after power off.

15 .   Resume Factory Settings

 - Before the machine is powered on, press the "Set" 

and "Up" buttons for 3 seconds at the same time. The machine will display "rS" 
for resume.  At this point factory settings will be reset. 

7

Содержание ULTIMA 186UVMC10

Страница 1: ...120V 1150W Includes 3 Filler Plates 100 Bags 25 10 x13 25 8 x12 25 12 x16 25 6 x10 Bags and Maintenance Kit Seal Bar Seal Tape Sealing Gasket 2 Fuses 186UVMC32 Double 16 Seal Bar 120V 1180W 11 2020 CHAMBER V ACUUM PACKAGING MACHINES ...

Страница 2: ...d Storage and Safety Information 3 Control Panel 4 5 Programming Instructions 6 7 Setup Instructions 8 Operating Instructions 9 10 Maintenance Guide 11 Troubleshooting 12 Model Specifications 13 Warranty 14 ...

Страница 3: ...d then submerge in cold water to stop the cooking process to kill any enzymes that may cause out gassing when vacuumed IMPORTANT NEVER vacuum pack garlic fungi like mushrooms or soft cheese like Brie Camembert and Ricotta A dangerous chemical reaction takes place when air is removed causing them to be extremely dangerous if ingested FOOD TYPICAL STORAGE VACUUM FRIDGE STORAGE VACUUM FREEZER STORAGE...

Страница 4: ...the Up Down buttons range of 0 6 seconds When the Cooling light is on adjust cooling time through the Up Down buttons range of 0 10 seconds 2 Indicator Light When switching settings using the Set button the corresponding indicator light will light up adjust time through the Up Down button 3 Marinate Button Press Marinate and the machine enters into marinate mode Press the Up Down buttons to choose...

Страница 5: ... Marinate time 27min Vacuum 20S 9 Marinate mode Marinate time 45min Vacuum 40S 6 Set Prog Button The preset program can be reset by the Set Prog button 1 Press the Prog 0 9 button first then press the Up Down buttons to select the program you wish to use 2 Press the Set button then press the Up Down buttons to set the required parameters 3 After setting the parameters press the Set Prog button and...

Страница 6: ...buttons and the 3 digit LED display will raise or lower the cooling time by 0 5 seconds press and hold for faster adjustment The time range for cooling is 0 5 seconds 6 Setting Marinate Mode Press the Marinate button and the Marinate light will come on Select the Marinate mode then press the Up Down buttons The 3 digit digital will raise or lower the marinate time by 9 minutes press and hold for f...

Страница 7: ... After 8 minutes the machine releases the air starts the cycle and continues to marinate until the marinate time countdown hits zero At that point the operation is completed 11 Cancel the Sealing Cooling Operation Press the Stop button to stop the operation and release the air while the machine is in the Sealing Cooling mode 12 Cancel the Gas Sealing Cooling Operation Press the Stop button to stop...

Страница 8: ...will not operate until all lights are off Adjusting Timing Controls Note All adjustments and changes to this unit s timing must be made with the lid lock disengaged and the lid open DO NOT use the machine with the lid lock engaged 8 1 Attach the power cord to the unit and plug the cord into a grounded electrical outlet 2 Release the lid lock located on the right side of the machine and allow the l...

Страница 9: ...rs of the lid for 3 4 seconds until the Vacuum cycle begins The unit will now enter into the VACPAK IT procedure as follows Vacuum mode begins air is removed from the chamber and pouch Sealing mode begins the seal bar heats and seals the pouch Cooling mode begins the seal is cooled to prevent melting The cycle finishes and the lid releases Note Some models have a manual Seal or Stop button that ca...

Страница 10: ...essure and must be shifted to a lower vacuum setting or the inflation of the bag with inert gas in order to counterbalance the pressure The gas flush system removes oxygen and simultaneously replaces it with a mixture of Carbon Dioxide and Nitrogen The combination of these gases will extend the shelf life of the product and will prevent any potential damage or breakage from the high pressure remov...

Страница 11: ...the unit 9 The oil has successfully been replaced and the unit is ready to use Changing Oil Routine Cleaning It is recommended to change the vacuum pump oil in your VACPAK IT machine after the first 20 hours of use Further oil changes should occur after every 50 hours of use Required Supplies Machine Oil Empty Oil Bottle with Spout Phillips Head Screwdriver Adjustable Wrench Oil Drain Pan or Conta...

Страница 12: ... the surface of the seal bar and inside of the bag and try again Bag loses vacuum after being sealed Check for sharp items such as bones stems cloves and others that can puncture the bags cover them with a folded paper towel and vacuum in a new pouch Some fruits and vegetables can release gases if not properly prepared before storing Make sure to blanch or freeze food before packaging If in doubt ...

Страница 13: ...HP Pump Life 200 000 Cycles 200 000 Cycles Vacuum Time 20 40 Seconds 20 40 Seconds Seal Time 0 6 Seconds 0 6 Seconds Features 10 Programmable Functions Digital Vacuum Pressure Display Traditional Analog Pressure Gauge Removable Seal Bar Easy Check and Fill Oil Pump Gas Flush System Adjustable Vacuum And Seal Time 10 Programmable Functions Digital Vacuum Pressure Display Traditional Analog Pressure...

Страница 14: ...Equipment where the serial number plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and damage due to improper maintenance wear and tear misuse abuse vandalism or Act of God Any action for breach of this warranty must be commenced within 18 months of the date on wh...

Отзывы: