background image

Control panel

4 .   "Up / Down" Button

 - By pressing the "Up / Down" button, you can adjust the 

vacuum time, sealing time, cooling time, marinate time, and the preset program. 
Press quickly or hold to move up or down. 

5 .   "Prog 0-9" Button

 - Press the "Prog 0-9" button (the LED display displays the 

corresponding number of the preset program; the other LED display shows the 
vacuum time or marinate time), then press the "Up / Down" buttons to choose the 
corresponding preset program (0-9 programs are optional). 

0-9 default program:

  

0:  Vac-Seal mode, Vacuum: 20S, Sealing: 2S, Cooling: 3S  
1:  Vac-Seal mode, Vacuum: 25S, Sealing: 2S, Cooling: 3S  
2:  Vac-Seal mode, Vacuum: 30S, Sealing: 2S, Cooling: 3S 
3:  Vac-Seal mode, Vacuum: 35S, Sealing: 2S, Cooling: 3S  
4:  Vac-Seal mode, Vacuum: 40S, Sealing: 2S, Cooling: 3S  
5:  Vac-Seal mode, Vacuum: 45S, Sealing: 2S, Cooling: 3S  
6:  Vac-Seal mode, Vacuum: 50S, Sealing: 2S, Cooling: 3S 
7:  Vac-Seal mode, Vacuum: 60S, Sealing: 2S, Cooling: 3S 
8:  Marinate mode, Marinate time: 27min., Vacuum: 20S 
9:  Marinate mode, Marinate time: 45min., Vacuum: 40S

6 .  "Set-Prog" Button

 - The preset program can be reset by the "Set-Prog" button: 

 

  1. Press the "Prog 0-9" button first, then press the "Up / Down" buttons to  

              select the program you wish to use. 
 

  2. Press the "Set" button, then press the "Up / Down" buttons to set the  

               required parameters. 
 

  3. After setting the parameters, press the "Set-Prog" button, and the machine 

              will emit a "beep", and the reset is done. 

7 .   "Stop"  Button

 - When in the vacuuming process (vacuum & seal or marinate 

mode), press the "Stop" button to enter the sealing mode. When the machine is 
working in sealing or cooling, press the "Stop" button to stop working.

8 .   LED  Display

 - Displays the vacuuming time, sealing time, cooling time and  

marinate time. 

9 .   LED  Display

 - Displays the corresponding sequence number for preset program.

10 .  Vacuum Gauge

 - Shows the vacuum level inside the vacuum chamber. 

11 .   Restore Factory Settings

 - Immediately after the machine is powered on, press 

and hold "Set" and the "Up" button to restore factory settings. The machine  
displays "rS" with a "beep", and the machine resumes factory settings.

5

Содержание ULTIMA 186UVMC10

Страница 1: ...120V 1150W Includes 3 Filler Plates 100 Bags 25 10 x13 25 8 x12 25 12 x16 25 6 x10 Bags and Maintenance Kit Seal Bar Seal Tape Sealing Gasket 2 Fuses 186UVMC32 Double 16 Seal Bar 120V 1180W 11 2020 CHAMBER V ACUUM PACKAGING MACHINES ...

Страница 2: ...d Storage and Safety Information 3 Control Panel 4 5 Programming Instructions 6 7 Setup Instructions 8 Operating Instructions 9 10 Maintenance Guide 11 Troubleshooting 12 Model Specifications 13 Warranty 14 ...

Страница 3: ...d then submerge in cold water to stop the cooking process to kill any enzymes that may cause out gassing when vacuumed IMPORTANT NEVER vacuum pack garlic fungi like mushrooms or soft cheese like Brie Camembert and Ricotta A dangerous chemical reaction takes place when air is removed causing them to be extremely dangerous if ingested FOOD TYPICAL STORAGE VACUUM FRIDGE STORAGE VACUUM FREEZER STORAGE...

Страница 4: ...the Up Down buttons range of 0 6 seconds When the Cooling light is on adjust cooling time through the Up Down buttons range of 0 10 seconds 2 Indicator Light When switching settings using the Set button the corresponding indicator light will light up adjust time through the Up Down button 3 Marinate Button Press Marinate and the machine enters into marinate mode Press the Up Down buttons to choose...

Страница 5: ... Marinate time 27min Vacuum 20S 9 Marinate mode Marinate time 45min Vacuum 40S 6 Set Prog Button The preset program can be reset by the Set Prog button 1 Press the Prog 0 9 button first then press the Up Down buttons to select the program you wish to use 2 Press the Set button then press the Up Down buttons to set the required parameters 3 After setting the parameters press the Set Prog button and...

Страница 6: ...buttons and the 3 digit LED display will raise or lower the cooling time by 0 5 seconds press and hold for faster adjustment The time range for cooling is 0 5 seconds 6 Setting Marinate Mode Press the Marinate button and the Marinate light will come on Select the Marinate mode then press the Up Down buttons The 3 digit digital will raise or lower the marinate time by 9 minutes press and hold for f...

Страница 7: ... After 8 minutes the machine releases the air starts the cycle and continues to marinate until the marinate time countdown hits zero At that point the operation is completed 11 Cancel the Sealing Cooling Operation Press the Stop button to stop the operation and release the air while the machine is in the Sealing Cooling mode 12 Cancel the Gas Sealing Cooling Operation Press the Stop button to stop...

Страница 8: ...will not operate until all lights are off Adjusting Timing Controls Note All adjustments and changes to this unit s timing must be made with the lid lock disengaged and the lid open DO NOT use the machine with the lid lock engaged 8 1 Attach the power cord to the unit and plug the cord into a grounded electrical outlet 2 Release the lid lock located on the right side of the machine and allow the l...

Страница 9: ...rs of the lid for 3 4 seconds until the Vacuum cycle begins The unit will now enter into the VACPAK IT procedure as follows Vacuum mode begins air is removed from the chamber and pouch Sealing mode begins the seal bar heats and seals the pouch Cooling mode begins the seal is cooled to prevent melting The cycle finishes and the lid releases Note Some models have a manual Seal or Stop button that ca...

Страница 10: ...essure and must be shifted to a lower vacuum setting or the inflation of the bag with inert gas in order to counterbalance the pressure The gas flush system removes oxygen and simultaneously replaces it with a mixture of Carbon Dioxide and Nitrogen The combination of these gases will extend the shelf life of the product and will prevent any potential damage or breakage from the high pressure remov...

Страница 11: ...the unit 9 The oil has successfully been replaced and the unit is ready to use Changing Oil Routine Cleaning It is recommended to change the vacuum pump oil in your VACPAK IT machine after the first 20 hours of use Further oil changes should occur after every 50 hours of use Required Supplies Machine Oil Empty Oil Bottle with Spout Phillips Head Screwdriver Adjustable Wrench Oil Drain Pan or Conta...

Страница 12: ... the surface of the seal bar and inside of the bag and try again Bag loses vacuum after being sealed Check for sharp items such as bones stems cloves and others that can puncture the bags cover them with a folded paper towel and vacuum in a new pouch Some fruits and vegetables can release gases if not properly prepared before storing Make sure to blanch or freeze food before packaging If in doubt ...

Страница 13: ...HP Pump Life 200 000 Cycles 200 000 Cycles Vacuum Time 20 40 Seconds 20 40 Seconds Seal Time 0 6 Seconds 0 6 Seconds Features 10 Programmable Functions Digital Vacuum Pressure Display Traditional Analog Pressure Gauge Removable Seal Bar Easy Check and Fill Oil Pump Gas Flush System Adjustable Vacuum And Seal Time 10 Programmable Functions Digital Vacuum Pressure Display Traditional Analog Pressure...

Страница 14: ...Equipment where the serial number plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and damage due to improper maintenance wear and tear misuse abuse vandalism or Act of God Any action for breach of this warranty must be commenced within 18 months of the date on wh...