maintenance guide
1. Warm up the current pump oil by running the machine for a few cycles.
2. Turn the unit off and disconnect the power cable from the outlet.
3. Remove the back panel of the unit by unscrewing the four corner screws.
4. Locate the oil drain bolt on the bottom of the vacuum pump under the unit’s housing.
Place an oil drain pan or container under the drain bolt. Remove the bolt and the oil
will begin to drain.
5. Once all oil has been drained, replace the oil drain bolt on the pump.
Note: Dispose of used machine oil properly according to your local and state
regulations.
6. Remove the oil fill bolt located on the vacuum pump using a wrench or similar tool.
7. Fill the pump with oil until the level is at least halfway up the sight glass. (Approx.
3.5 oz. of oil).
8. Replace the oil fill bolt on the vacuum pump, and then replace the back panel on
the unit.
9. The oil has successfully been replaced and the unit is ready to use.
Changing Oil
Routine Cleaning
It is recommended to change the vacuum pump oil in your VACPAK-IT machine after the
first 20 hours of use. Further oil changes should occur after every 50 hours of use.
Required Supplies:
• Machine Oil
• Empty Oil Bottle with Spout
• Phillips Head Screwdriver
• Adjustable Wrench
• Oil Drain Pan or Container
• After each day’s use or when the machine is dirty, remove the seal bar and wipe down
the chamber, lid and exterior with a damp cloth and mild soap to remove food particles
and other debris.
• The seal bar should be wiped clean with a damp cloth only.
• Never use an acetone, acetone-based or abrasive cleaner on the lid or other plastic
parts. Parts can become discolored, scratched, or even appear burned if these materials
are used.
• The stainless steel housing should be cleaned and cared for by using a traditional
stainless steel cleaning material.
• Inspect the power cord for tears, frays, or other damage. Do not use machine if the
power cord is damaged.