Brake Chopper Application – Parameter lists
vacon • 9
24-hour s358 (0)40 8371 150 • Email: [email protected]
3.4
Output signals (Control keypad: Menu G2
Æ
G2.3)
3.4.1 Digital
outputs
(G2.3.1)
Code
Parameter
Default
Min
Max
Unit
ID
Note
P2.3.1.1
1
0
6
1216
Signal Selection for DO1
P2.3.1.2
2
0
6
1217
Signal selection for DO2 (RO1)
P2.3.1.3
3
0
6
1218
Signal selection for DO3 (RO2)
P2.3.1.4
0
0
6
1385
Signal Selection for DO4
P2.3.1.5
0
0
6
1386
Signal selection for DO5
P2.3.1.6
0
0
6
1390
Signal selection for DO6
P2.3.1.7
0
0
6
1391
Signal Selection for DO7
P2.3.1.8
0
0
6
1395
Signal selection for DO8
P2.3.1.9
0
0
6
1396
Signal selection for DO9
P2.3.1.10
0
0
6
1423
Signal Selection for DO10
P2.3.1.11
0
0
6
1427
Signal selection for DO11
P2.3.1.12
0
0
6
1428
Signal selection for DO12
P2.3.1.13
0
0
6
1429
Signal selection for DO13
Table 3-5. Digital output parameters G2.3.1
3.4.2 Analog output 1 (G2.3.2)
Code
Parameter
Default
Min
Max
Unit
ID
Note
P2.3.2.1
0 0 2000
1233
Set the ID no. of a signal to be
connected to AO1
P2.3.2.2
0 0 1
1234
Minimum voltage or current
at AO1. 0= 0V/0mA, 1= 4mA
P2.3.2.3
0,02
10,00
s
1235
Filter time for the signal
selected for AO1 in Seconds.
P2.3.2.4
1500
-30000 30000
1236
Maximum value of a signal
selected for AO1. This will
correspond to +10V/20mA.
P2.3.2.5
-30000
30000
1237
Minimum value of a signal
connected to AO1. This will
correspond to 0V/0mA or
2V/4mA depending on the
type of AO1.
Table 3-6. Analog output parameters G2.3.2
3.5
BCU In parallel (Control keypad: Menu G2
Æ
G2.4)
Code
Parameter
Default
Min
Max
Unit
ID
Note
P2.4.1
0,00
100,00
%
620
Increase in braking current
will increase the DC link
voltage level for operation as
a function of drooping.
Table 3-7. BCU In Parallel parameters G2.4