8 • vacon
Brake Chopper Application – Parameter lists
Tel.+358 (0)201 2121 • Fax +358 (0)201 212 205
3.2
Basic parameters (Control keypad: Menu G2
Æ
G2.1)
Code
Parameter
Default
Min
Max
Unit
ID
Note
P2.1.1
648
BrakeChopperLev
elMin
BrakeChopperLev
elMax
V 1267
Brake chopper operation
level in volts
P2.1.2
0
1
631
Manual identification for
brake resistor connection.
Table 3-2. Basic parameters G2.1
3.3
Input signals (Control keypad: Menu G2
Æ
G2.2)
3.3.1 Digital inputs (G2.2.1)
Code
Parameter
Default
Min
Max
Unit
ID
Note
P2.2.1.1
3 0 6
1208
Input Selection for Fault
Resetting.
0 = Not used
1 = DIN1
2 = DIN2
3 = DIN3
4 = DIN4
5 = DIN5
6 = DIN6
P2.2.1.2
0 0 6
1214
Digital input selection for
external fault signal
connection.
As par. P2.2.1.1
P2.2.1.3
6 0 6
1212
Input selection for Run
Enable Ctrl. 0 = Run
Enabled internally
As par. P2.2.1.1
P2.2.1.4
0
6
1209
Input Selection for KLIXON
type Temperature Sensor.
As par. P2.2.1.1
Table 3-3. Digital input parameters G2.2.1
3.3.2 Analog
inputs
(G2.2.2)
Code
Parameter
Default
Min
Max
Unit
ID
Note
P2.2.2.1
0 0 2
1221
Select the Analog input for
connecting PT100 Sensor.
0=Not Used,
1=AI1,
2=AI2
P2.2.2.2
0 0 2
1222
Number of PT100 elements in
series.
0=1*PT100,
1=2*PT100,
2=3*PT100.
Table 3-4. Analog input parameters G2.2.2