RECEIPT OF DELIVERY
Vacon NX inverters have undergone scrupulous tests and quality checks at the factory before they
are delivered to the customer. However, after unpacking the product, check that no signs of
transportation damage is to be found on the product and that the delivery is complete (compare the
type designation of the product to the code below, see Figure 3-1
Should the drive have been damaged during the shipping, please contact primarily the cargo
insurance company or the carrier.
If the delivery does not correspond to your order, contact the supplier immediately.
3.1
Type designation code.
3.1.1
FI9 – FI14
Figure 3-1 Vacon NX type designation code, FI9 – FI14
NX
AAAA
T 0 C S S A1A2000000
V
2
A
I
Nominal current (low overload)
0004 = 4A, 0520 = 520A, etc.
Nominal supply voltage (3-phase):
5 = 380–500Vac / 465–800Vdc
6 = 525–690Vac / 640–1100Vdc
Control keypad:
A = standard (alpha-numeric)
B = no local control keypad
F = dummy keypad
G = graphic display
Enclosure class:
2 = IP21, FR4...7
0 = IP00, FR8, FI9...14
EMC emission level:
T = fulfils standard EN61800-3 for IT networks
0 = N/A (no brake chopper)
Hardware modifications; Module type - S - Boards
S = Direct connection, standard boards, FR4...8
V = Direct connection, varnished boards, FR4...8
F= Fiber connection, standard boards
G = Fiber connection, varnished boards
Option boards; each slot is represented by two characters where:
A = basic I/O board, B = expander I/O board,
C = fieldbus board, D = special board
S = Standard air cooled drive
A = Standard air cooled power unit - transformer supply for main fan
U = Standard air cooled power unit - external supply for main fan
C = INU - with integrated charging circuit
I = INU - no charging circuit
N = Standard 6-pulse - no chokes
S = Standard 6-pulse connection with chokes
2 = AFE module
5 = AFE LCL filter
3 = FFE module
6 = FFE AC choke
8 = BCU Brake chopper unit
Module type:
A = AFE Active Front End
B = BCU Brake Chopper Unit
F = FFE Fundamental Front End
I = INU Inverter
N = Non regenerative Front End
Product generation
Содержание NXI
Страница 1: ...vacon nxi inverters fi9 fi14 user manual ...
Страница 24: ...24 vacon installation Tel 358 201 2121 Fax 358 201 212 205 5 Figure 5 2 Vacon NXI dimensions FI10 ...
Страница 26: ...26 vacon installation Tel 358 201 2121 Fax 358 201 212 205 5 Figure 5 4 Vacon NXI dimensions FI12 front view ...
Страница 104: ......