• vacon
Profinet IO
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
2
Response Header, Meaning of the fields
Field
Meaning
Range
Request Reference
Mirrored from request.
1…255
Response ID
Slave’s response.
0x01 = Request OK
0x02 = Change OK
0x81 = Request Failed
0x82 = Change Failed
DO-ID
Mirrored from request.
-
Number of Parame-
ters
Number of parameters in response.
1…38
Format
Data type of response value.
0x00 = Reserved
0x01 – 0x36 = Data types
0x37 – 0x3F = Reserved
0x40 = Zero
0x41 = Byte
0x42 = Word
0x43 = Double word
0x44 = Error
0x45 – 0xFF = Reserved
Number of Values
Number of values in response.
1…234
Value
Value of request.
-