6 • vacon
TECHNICAL SPECIFICATIONS
Tel: +358-201-2121 • Fax: +358-201-212 205
2.
TECHNICAL SPECIFICATIONS
2.1
Inverter ratings
Range of input voltages 340-800Vcc, 50 Hz, 3~
Inverter
type
Nom. output
power
[kW]
Recommended
max PV power
[kW]
Max al-
lowed PV
power
[A]
Max effi-
ciency [%]
Power con-
sumption at
night
[W]
Inverter
dimensions
[mm]
Inverter
weight
[kg]
NXV0010
10
12
50
>94%
<5
600x1481x600
220
NXV0015
15
18.5
50
>94%
<5
600x1481x600
220
NXV0020
20
24
99
>94%
<5
600x1481x600
300
NXV0025
25
30
99
>94%
<5
600x1481x600
300
NXV0030
30
36
99
>94%
<5
600x1481x600
300
NXV0040
40
48
198
>95%
<30
800x1881x600
550
NXV0050
50
60
198
>96%
<30
800x1881x600
550
NXV0080
80
96
353
>96%
<30
800x2281x600
850
NXV0100
100
120
353
>96%
<30
800x2281x600
850
Table 2-1. Power ratings, dimensions and weights
2.2
Technical data
DC Input
Range of input voltages 340...800 VDC
Maximum input voltage 900 VDC
AC Output
Mains voltage
3*400 ± 10%
Galvanic isolation
For each isolator transformer attached
Frequency
50/60 Hz ± 0,5%
Cos
φ
>0.99, for output 20%-100% of Pn
Harmonic distortion
< 2.5% for output > 30% of power
Consumption at night
< 5W (NXV0010...NXV0030); <30 W (NXV0040...NXV0100)
Maximum efficiency
> 94...96%
Ambient temperature
-10...+40°C; 1-% derating for each degree up to 50°C required
Relative humidity
< 95% no condensation
Protection
IP21
Display
Alfanumeric display per unit with two lines of 14 characters, leds
indicating functioning, plus fault and function push buttons.
Signalling
3 potential free contacts to indicate faults and alarms
Communications
May include one of the following communication buses as an op-
tional feature: Modbus RTU, Ethernet (Modbus/TCP), RS485, GPRS,
string and inverter monitoring
May include a monitoring system with http-access as an optional
feature.
IEC61000-3-3
For the product to meet the technical requirements of IEC 61000-3-
3, the supply should have a system impedance accordingly:
≤
NXV0015: Zsys = 0.105 ohm
≤
NXV0030: Zsys = 0.270 ohm
≤
NXV0050: Zsys = 0.176 ohm
≤
NXV0100: Zsys = 0.136 ohm
Ambient condi-
tions
Altitude
Max. 2,000m
Environmental category
Indoor, conditioned
Pollution degree
PD2
Overvoltage
category
AC (Mains)
OVCIII
DC (Panels)
OVCII
Table 2-2. Technical data