TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The air mover will not
operate.
No power supply.
Check the power supply, cord,
breakers, and fuses.
Faulty power cord.
Unplug and visually check the
power cord. If damaged, have it
repaired by qualified personnel or
contact the after sales helpline.
On/off switch in the wrong
position.
Move the switch to the "I" ON
position.
The on/off switch is faulty.
Have the switch replaced by
qualified personnel or contact the
after sales helpline.
The air mover runs but
makes loud scraping
noise.
Damage to the unit has
caused deformed housing or
misaligned centrifugal fan.
Replace the air mover.
The air mover runs but
centrifugal fan does not
rotate.
The centrifugal fan and
housing are jammed.
Replace the air mover.
There is a problem with the
switch or capacitor.
The air mover runs briefly
then shuts off due to
overload protection.
The intake grill or air
discharge grill is obstructed.
Remove the obstruction.
The motor is damaged.
Replace the air mover.
The air mover runs but
with excessive vibration.
The centrifugal fan has dirt
build up.
Have the air mover inspected by
qualified personnel or contact the
after sales helpline.
The centrifugal fan is
damaged or the motor is bent.
Replace the air mover.
The remote control will not
operate.
The remote control is not
paired with the air mover.
Reset the remote control following
the instructions on page 10.
The battery is dead.
Replace the battery or remote
control.
The remote control is
damaged.
Replace with a new remote
control.
The status light on the
remote control no longer
illuminates when pressed.
The battery is dead.
Replace the battery or remote
control.
The remote control is
damaged.
Replace with a new remote
control.
WARNING:
To reduce the risk of electric shock, unplug before troubleshooting.