background image

9

GB

MAINTENANCE

WARNING:

 Do not store outdoors. Store in a dry environment, away from 

hazardous materials, such as toxic, carcinogenic, flammable, or explosive substances.

CAUTION:

 

To prevent damage to air mover, property damage, or personal injury: 

do not stack more than three units high. Stack only on a stable, level, even surface. Do not 
transport stacked units unless they are braced on all sides.

CAUTION:

 

Do not turn on the air mover while it is stacked. The stacking pegs are 

for storage purposes only.

1. Maintenance Before and After Each Use

1)  Inspect the plug and the cord to ensure that it has not been damaged during operation or 

between uses. If the plug or cord is damaged, do not use the air mover and replace the 

damaged part immediately.

2)  Check the air intake and air discharge grills and make sure they are free of blockage.

2. Cord Storage

1)  Before storing the air mover, ensure the on/off switch is turned to "0" OFF position, and unplug 

the unit from the power outlet.

2)  Wrap the power cord around the base of the handle.
3)  Use the attached power cable strap to hold the cord in place.

3. Storing the Air Mover

To conserve space while storing multiple units, this air mover can be stacked together with multiple 
additional units using the mounting pegs and inlets on each side of the unit (Fig. 5).

4. Replacing the Remote Control Battery

NOTE: 

The remote control contains small parts. Be careful when replacing the battery and ensure 

all maintenance is completed on a flat and stable surface.
1)  Locate the 3 screws on the rear of the remote control. Carefully remove these screws and keep 

them in a safe place.

2)  Remove the rear casing to access the battery. The battery and board can both be removed (Fig. 6).

 

3)  Replace the battery with a suitable 27A 12V battery cell. Ensure the positive and negative 

battery connections are correctly positioned.

4)  Insert the board and battery back into the casing and secure in place by retightening the screws 

provided.

CAUTION: 

Check that the new battery is installed correctly by pressing a button 

on the remote control. The indicator light (

) should illuminate RED (Fig. 7).

WARNING: 

Ensure that the unit is never operated without the intake grills, air 

discharge grill, and impeller.

Содержание CARDIO54 AM1202R

Страница 1: ...AM1202R 124W ...

Страница 2: ......

Страница 3: ...1 2 3 4 5 9 10 6 11 12 13 7 8 ...

Страница 4: ... 7 7 9 10 11 11 Thank you for purchasing this Vacmaster Air Mover Feel confident that with Vacmaster you are obtaining a high quality product engineered for optimal performance FOR YOUR SAFETY CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS SYMBOLS Caution Read instruction manual Failure to follow the warnings and instructions may result in electric shock fire and or serious injury ...

Страница 5: ... appliance Cleaning and user maintenance shall not be made by children without supervision Never leave the appliance switched on unattended if you leave the work area switch the appliance off or unplug it from the power supply Do not use this air mover near flammable liquids gases or explosive vapours like gasoline or other fuels lighter fluids cleaners oil based paints natural gas hydrogen or exp...

Страница 6: ...expose to rain Store indoors Do not handle the plug or air mover with wet hands Do not run cord under carpeting Do not cover cord with throw rugs runners or other coverings Direct cord away from traffic areas where it will not be tripped over Do not cover the ventilation openings Do not operate with any ventilation openings blocked keep free of dust lint hair or anything that may reduce air flow N...

Страница 7: ...he speed control knob is located at position the remote control mode is engaged For remote control operation refer to the Remote Control Mode section 6 To switch off the air mover press the on off switch to 0 OFF position Position Status I Low II Medium III Maximum Remote Control Mode UNPACKING AND CHECKING CARTON CONTENTS 2 Remote Control Mode NOTE The remote control supplied with your air mover ...

Страница 8: ...s 4 Affixing Remote Control Strap The remote control can be conveniently stored in the holder located on the strap 1 Place the remote control unit into the holder within the strap Remote control should sit securely 2 The strap can be used to attach onto a handle located for example on a treadmill or exercise bike To secure the strap loop the strap around the handle and secure the locking tap into ...

Страница 9: ...the base of the handle 3 Use the attached power cable strap to hold the cord in place 3 Storing the Air Mover To conserve space while storing multiple units this air mover can be stacked together with multiple additional units using the mounting pegs and inlets on each side of the unit Fig 5 4 Replacing the Remote Control Battery NOTE The remote control contains small parts Be careful when replaci...

Страница 10: ...pacitor The air mover runs briefly then shuts off due to overload protection The intake grill or air discharge grill is obstructed Remove the obstruction The motor is damaged Replace the air mover The air mover runs but with excessive vibration The centrifugal fan has dirt build up Have the air mover inspected by qualified personnel or contact the after sales helpline The centrifugal fan is damage...

Страница 11: ...hroughout the EU The machine must be delivered in rigid packaging to avoid damage during transportation The packaging and the machine itself are manufactured from recyclable materials and should be disposed of accordingly TECHNICAL DATA Model Number AM1202R Motor 220 240V 50Hz Power 124W Air flow 15m3 min Net Weight 3 63Kg ...

Страница 12: ......

Страница 13: ......

Страница 14: ...4 1 6 7 5 2 3 ...

Страница 15: ......

Страница 16: ...AM1202R Suzhou Cleva Electric Appliance Co Ltd No 8 Ting Rong Street Suzhou Industrial Park Suzhou Jiangsu Province China www cleva europe com Made in P R C ...

Отзывы: