8.10 -
ADI INTERFACE
The ADI (Additional Devices Interface) interface of the control
unit PD15 allows the connection to V2 optional modules.
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
m
WARNING: Please read the instructions of each single
module to install the optional modules.
For some devices, it is possible to configure the mode for
interfacing with the control unit; in addition, it is necessary to
enable the interface so that the control unit can process the
signals arriving from the ADI device.
Please refer to the
i.ADi
programming menu to enable the ADI
interface and access the device configuration menu.
ADI devices use the display of the control unit to issue alarms or
display the configuration of the control unit.
NOTE:
If the ADI interface is not enabled (no device
connected), the segments remain turned off.
The device connected to the Adi interface is able to signal to the
control unit three alarm signals, which are displayed on the
control unit display as follows:
•
PHOTOCELL ALARMS
-
the upper segment comes on
:
the door stops moving, when the alarm stops opening
restarts.
•
EDGE ALARM
-
the lower segment comes on
:
inverts motion of the door for 3 seconds.
•
STOP ALARM
-
both segments start flashing
:
the door stops and cannot restart until the alarm stops.
A1
Antenna shield
A2
Antenna
J1
Safety ribbons.
N.C. contact or conductive rubber ribbons
J2
Open command for connecting traditional
devices with N.O. contact
J3
STOP command. N.C. contact
J4
Common (-)
J5
Photocell. N.C. contact
J6 - J7
24Vdc supply for photocells and other
accessories
J7 - J8
Photocell TX power supply for functional test
J7 - J9
Warning light
B1 - B2
Dry contact for low-voltage light output
L
Power phase
N
Neutral
EARTH - electric system ground
F1
T1,6A
OVERLOAD
It shows that there is an overload on accessories
power supply
MASTER-SLAVE
Linking connector MASTER-SLAVE of two
motors through the cable identified by
code 162416
ADI
Connector for ADI module insertion
RECEIVER
Connector for MR2 receiver module
insertion
FC
Connector linked to the limit
micro switches
MOTOR
Connector linked to the motor
EARTH
Grounding terminal connected to the
motor
8.11 -
ELECTRICAL CONNECTION
Содержание VEGA-24V
Страница 2: ......
Страница 17: ...ITALIANO 15...
Страница 38: ...ITALIANO 36...
Страница 53: ...ENGLISH 51...
Страница 74: ...ENGLISH 72...
Страница 89: ...FRAN AIS 87...
Страница 110: ...FRAN AIS 108...
Страница 125: ...ESPA OL 123...
Страница 146: ...ESPA OL 144...
Страница 147: ......
Страница 148: ......