Lock advance time
While the electric lock is energised, the door doesn't move for the
t.ASE
time, to help release.
If the
t.ASE
time is lower than
t.SEr
, the lock keeps being energised
while the door begins to move.
m
WARNING: If the door is not equipped with an electric lock
set the 0 value.
Backlash time
It could be useful to give a closing command to the motor, to help the
electric lock release.
The control unit controls the motor in reduced power in closing
direction for the setup time.
The backlash precedes the electric lock release. It is possible to reverse
the order by setting a lock advance time higher then the backlash one.
m
WARNING: If the door is not equipped with an electric lock
set the no value.
Motor power during opening
This menu allows to adjust the motor power during opening.
The displayed value represents the percentage with respect to the
maximum motor power.
Pre-blinking time
Before any gate movement, blinker will be activated for
t.PrE
time, to
warn about the incoming motion.
Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(while keeping the time set in the
t.PrE
menu for opening).
If no is selected, the pre-flashing time set in the
t.PrE
menu is used
during opening and closing.
If it is only desired to set pre-flashing for closure, simply set a value for
t.PCh
and select no for the
t.PrE
menu
NOTE: it is not possible to set pre-flashing for opening only.
Содержание VEGA-24V
Страница 2: ......
Страница 17: ...ITALIANO 15...
Страница 38: ...ITALIANO 36...
Страница 53: ...ENGLISH 51...
Страница 74: ...ENGLISH 72...
Страница 89: ...FRAN AIS 87...
Страница 110: ...FRAN AIS 108...
Страница 125: ...ESPA OL 123...
Страница 146: ...ESPA OL 144...
Страница 147: ......
Страница 148: ......