ENGLISH
1
Mechanical safety rib (CMS)
2
Opening command to connect VRD (data input)
3
Opening command to connect traditional
devices having normally open contact
4
Stop command. Normally closed contact
5 - 8 - 11
Common (-)
6
Photocell. Normally closed contact
7
+24VDC 10W photocell (RX) power supply and
other accessories
9
+24VDC 10W blinker
10
Compulsory TX photocells power 24VDC
1W for check test
12
+24VDC 3W Pilot light
13 - 14
Power supply
15
Antenna gearbox
16
Antenna hearth brade
17
YELLOW: position sensor (level zero)
18
BLACK: position sensor (level zero)
19
RED: position sensor (level zero)
20
GREEN - 24VDC motor output
21
BROWN - 24VDC motor output
22 - 23 - 24
ENCODER
L1
Courtesy lamp model E14
m
CAUTION:
UNUSED INPUTS THAT ARE NORMALLY
CLOSED (CMS, STOP, PHOTOCELL) SHOULD BE CONNECTED TO
THE COMMON WIRE (-).
ELECTRIC CONNECTIONS
Carefully read the paragraph “IMPORTANT WARNING” at the
previous page.
• Open the guard by turning at 90° the push-button P1.
• As far as the connections are concerned, please see the
paragraph “CONNECTIONS TO TERMINAL BOARD”, fixing the
cable output as the illustration explains.
• Once the connections have been carried out, close the guard
and turn the push-button to its original position.
27