ENGLISH
- 49 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
Pot
Motor power
60
(STD)
100
(FAST)
30 - 100
The displayed value is the percentage of max. motor power
P.rAL
Power motor during slow-down phase
20
0 - 70
The value displayed represents the percentage of the maximum motor
power
Po.AL
Power used for the realignment on the limit
30
(STD)
25
(FAST)
0 - 70
Power used in searching for the position of the limit, in self-learning
phases or after reset
SPUn
Start off
If this function is activated, for the first 2 seconds of motion of each door,
the control unit will ignore
Pot
value and it will give motor the maximum
power command in order to overcome the gate inertia
no
no
Function deactivated
Si
Function activated
rAM
Starting ramp
1
(STD)
3
(FAST)
6 - 0
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
SEnS
Adjusting the obstacle sensor
no
no
Function deactivated
1.0A-16.0A
This menu allows adjustment of the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the value set, the
control unit detects an alarm
rA.AP
Slow down in opening
20
(STD)
25
(FAST)
0 - 100
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last opening stretch
rA.Ch
Slow down in closing
20
(STD)
25
(FAST)
0 - 100
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last closing stretch
St.AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
St.Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
StoP
StoP
The gate stops and its cycle is considered as finished
APEr
The gate opens again