20
GATE DELAY DURING OPENING
In order to avoid any collision of the gate during the opening
phase, the time of delay should be introduced r.AP, which is
adjustable from 0 to 2 minutes. In such a case the opening
time of gate 2 is delayed in comparison to the gate 1.
This type of programming allows loading the V2 ELETTRONICA
default program in the memory: the standard data that will
be inserted automatically are shown in the table below (in
the column DEFAULT DATA).
Set the wished function pressing the up or DOWN keys and
press MENU key to confirm.
GATE 1 OPENING TIME
This menu is adjustable from 0 to 2 minutes and
determines the time of opening of gate 1.
GATE 2 OPENING TIME
This menu is adjustable from 0 to 2 minutes and
determines the time of opening of gate 2.
WARNING: if it is a one-door gate, such time shall be set up
on 0.
OPENING TIME OF PEDESTRIAN GATE
This menu is adjustable from 0 seconds to t.AP1 and
determines the opening time of pedestrian gate.
CLOSING TIME GATE 1
This menu is adjustable from 0 to 2 minutes which is the
closing time for gate 1. To avoid the uncompleted closing of
the gate, we suggest to set a longer opening time of t.AP1.
CLOSING TIME GATE 2
This menu is adjustable from 0 to 2 minutes which is the
closing time for gate 2. To be sure of the perfect closing of
the gate, we suggest to set a longer opening time t.AP2.
CLOSING OF PEDESTRIAN GATE
This menu is adjustable from 0 to t.Ch1 and determines the
closing time of gate 1. In order to avoid the uncompleted
closing of the gate, we suggest to set a longer opening time
of t.APP.
Содержание City2
Страница 2: ...City2 ISTRUZIONI 1 INSTRUCTIONS 15 NOTICES 29 ANLEITUNGEN 43 INSTRUCCIONES 57 I GB F D E ...
Страница 16: ...14 NOTE ...
Страница 30: ...28 NOTE ...
Страница 44: ...42 NOTA ...
Страница 58: ...56 BEMERKUNGEN ...
Страница 72: ...70 NOTA ...