17
Other characteristics:
•
Self-secured power against short circuits inside the
gearcase, on motors and relevant connected
accessories.
•
Power adjustment by means of current shutting
(PWM: Power motor controller).
•
Obstacle detection by means of monitoring the
motor absorbed current.
•
Operation without the network voltage by means of
buffer battery (optional).
•
Warning light showing the status of the gate.
•
Programmable logic auxiliary relay for courtesy
lights or other use.
City2
gearcase has been prearranged for the coupling
of a Personal Pass MR1 receiver having a high-sensiti-
vity super-heterodyne architecture.
m
ATTENTION: it is necessary to turn off the
control unit power before doing the operations
mentioned here below. Please pay attention to
the way you connect the removable modules.
PLUGGING THE MR1 RECEIVER
MODULE IN
MR1 module receiver is provided with 4 channels and
each of them is suitable for a command of
City2
con-
trol unit:
CHANNEL 1
rt
START
CHANNEL 2
rt
PEDESTRIAN
START
CHANNEL 3
rt
STOP
CHANNEL 4
rt
COURTESY LIGHTS
m
Before programming 4 channels and function
logics read carefully the instructions of MR1.
WARNING
: we suggest to use the external
aerial (model:
ANS433
) in order to
guarantee the maximal range.
TERMINAL CONNECTION
Antenna
Antenna shield
Opening control for the connec-
tion of control devices with
normally open contact
Opening controls for pedestrian
access for the connection of
control devices with normally
open contact
Common (-)
STOP command
Normally closed contact
Photocell 1
Normally closed contact
Photocell 2
Normally closed contact
Common (-)
Power 12VDC for photo-
cells and other accessories
Electric lock 12VAC
Warning light 24VAC 3W
Power output 24VDC
for motor 2
Power output 24VDC
for motor 1
Backup battery 12VDC
Courtesy light
230VAC - 10W (
City2
)
120VAC - 10W (
City2-120V
)
Flashing light
230VAC - 40W (
City2
)
120VAC - 40W (
City2-120V
)
Neutral 230 / 120 VAC
Phase 230 / 120 VAC
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.-12.
13.-14.
15.-16.
17.-18.
19.-20.
21.-22.
23.- 24.
25.
26.
BUTTON
P1
LED
L1
Содержание City2
Страница 2: ...City2 ISTRUZIONI 1 INSTRUCTIONS 15 NOTICES 29 ANLEITUNGEN 43 INSTRUCCIONES 57 I GB F D E ...
Страница 16: ...14 NOTE ...
Страница 30: ...28 NOTE ...
Страница 44: ...42 NOTA ...
Страница 58: ...56 BEMERKUNGEN ...
Страница 72: ...70 NOTA ...