Ethernet / DMX operation
Options “Ethernet/DMX” has to be selected from the “Ethernet Mode” menu on the first fixture (connected to
the Ethernet) in the fixture chain,next fixtures have standard DMX setting.
Connect the Ethernet-input of the first fixture in the data chain with the network. Connect the DMX output of
this fixture with the input of the next fixture until all fixtures are connected to the DMX chain.
Caution:
At the last fixture, the DMX chain has to be terminated with a terminator. Solder a 120
Ω
resistor
between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the last fixture.
Example:
DMX address=1
DMX address=33
DMX address=129
IP addres=002.168.002.002
Universe=0
DMX address=1
DMX address=33
DMX address=129
IP addres=002.168.002.003
Universe=1