background image

DMX

 

protocol

1

2

3

Mode/channel

DMX

 

Value

Function

Type

 

of

 

control

200

 ‐ 

201 Open/hole

  

step

202

 ‐ 

221 Forwards

 

gobo

 

wheel

  

rotation

 

from

 

fast

 

to

 

slow

proportional

222

 ‐ 

223 No

 

rotation

step

224

 ‐ 

243 Backwards

 

gobo

 

wheel

  

rotation

 

from

 

slow

 

to

 

fast

proportional

244

 ‐ 

249 Random

 

gobo

  

selection

 

by

 

audio

 

control

step

(Set

 

microphone

 

sensitivity

 

in

 

menu

 

„Personality”)

250

 ‐ 

255 Auto

 

random

 

gobo

  

selection

 

from

 

fast

 

to

 

slow

proportional

18

16

14

Rot.

 

gobo

  

indexing

 

and

 

rotation

Gobo

 

indexing

  ‐ 

set

 

position

 

on

 

channel

 

17/15/13

0

 ‐ 

255

Gobo

 

indexing

proportional

Gobo

 

rotation

  ‐ 

set

 

position

 

on

 

channel

  

17/15/13

0

No

 

rotation

step

1

 ‐ 

127

Forwards

 

gobo

 

rotation

 

from

 

fast

 

to

 

slow

proportional

128

 ‐ 

129 No

 

rotation

step

130

 ‐ 

255 Backwards

 

gobo

 

rotation

 

from

 

slow

 

to

 

fast

proportional

19

*

*

Rot.

 

gobo

 

indexing/rotation

 ‐ 

fine

0

255

Fine

 

indexing

 

(rotation)

proportional

20

17

15

Prism

0

 ‐ 

19

Open

 

position

 

(hole)

step

20

 ‐ 

127 3

facet

 

rotating

 

prism

step

128

 ‐ 

255 Prism/gobo

 

macros

128

 ‐ 

135 Macro

 

1

step

136

 ‐ 

143 Macro

 

2

step

144

 ‐ 

151 Macro

 

3

step

152

 ‐ 

159 Macro

 

4

step

160

 ‐ 

167 Macro

 

5

step

168

 ‐ 

175 Macro

 

6

step

176

 ‐ 

183 Macro

 

7

step

184

 ‐ 

191 Macro

 

8

step

192

 ‐ 

199 Macro

 

9

step

200

 ‐ 

207 Macro

 

10

step

208

 ‐ 

215 Macro

 

11

step

216

 ‐ 

223 Macro

 

12

step

224

 ‐ 

231 Macro

 

13

step

232

 ‐ 

239 Macro

 

14

step

240

 ‐ 

247 Macro

 

15

step

248

 ‐ 

255 Macro

 

16

step

21

18

16

Prism

 

rotation

0

No

 

rotation

step

1

 ‐ 

127

Forwards

 

rotation

 

from

 

slow

 

to

 

fast

proportional

128

 ‐ 

129 No

 

rotation

step

130

 ‐ 

255 Backwards

 

rotation

 

from

 

slow

 

to

 

fast

proportional

22

19

17

Frost

0

Open

step

1

 ‐ 

179

Frost

 

from

 

0%

 

to

 

100%

proportional

180

 ‐ 

189 100%

 

frost

step

190

 ‐ 

211 Pulse

 

closing

 

from

 

slow

 

to

 

fast

proportional

212

 ‐ 

233 Pulse

 

opening

 

from

 

fast

 

to

 

slow

proportional

234

 ‐ 

255 Ramping

 

from

 

fast

 

to

 

slow

proportional

23

20

18

Iris

Page

 

5

Содержание Robin 300 plasma spot

Страница 1: ...Version1 6...

Страница 2: ...Rigging the fixture 8 4 5 DMX 512 connection 10 4 6 Ethernet connection 11 5 Remotely controllable functions 13 6 Control menu map 14 7 Control menu 17 7 1 Tab Address 18 7 2 Tab Information 18 7 3 T...

Страница 3: ...ll connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power swit...

Страница 4: ...area below the installation place is blocked when rigging derigging or servicing the fix ture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct hole only Only...

Страница 5: ...SCAPE button 3 NEXT button 4 ENTER DISPLAY ON button 5 PREV button The head should be locked for transportation the tilt lock latch 2 and the pan lock latch 3 have to be in the locked positions To unl...

Страница 6: ...t automatically adjusts to any 50 60Hz AC power source from 100 240 Volts Install a suitable plug on the power cord note that the cores in the power cord are coloured according to the following table...

Страница 7: ...under the distance stop and push the gobo module into hole in the static gobo wheel 5 Replace the top cover before applying power Rotating gobos 1 Disconnect the fixture from mains and allow it to coo...

Страница 8: ...ifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury or damage to property The fixture has to be insta...

Страница 9: ...Pull the safety wire 2 through the carrying handles 5 and around the truss 6 as shown on the pictures below Securing the fixture via one safety wire Securing the fixture via two safety wires When inst...

Страница 10: ...er directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR out puts you need to use adapter cables Building a serial DMX chain Connect t...

Страница 11: ...6 RX 3 RX 7 Not connected 4 Not connected 8 Not connected Patch cables that connect fixtures to the hubs or LAN sockets are wired 1 1 that is pins with the same numbers are connected together 1 1 2 2...

Страница 12: ...ect the DMX output of this fixture with the input of the next fixture until all fixtures are connected to the DMX chain Caution At the last fixture the DMX chain has to be terminated with a terminator...

Страница 13: ...nuous range of colors may be achieved by varying the amount of each filter from 0 to 100 Colour temperature correction filter lowers the colour temperature from 6000 K to 3200 K Note After 1500 operat...

Страница 14: ...Lamp On Time Total Hours Resetable Hours Lamp Strikes Total Strikes Resetable Strikes Air Filters Elapsed Time Alert Period 10 300 Fixture Temperatures Head Temperature Current Maximum NonRes Maximum...

Страница 15: ...Wheel Moving Off On Gobo Wheels Moving Off On Init Effect Positions Pan 0 255 Dimmer Fine 0 255 Screen Settings Display Intensity 1 10 Screen Saver Delay Off 10min Touchscreen Lock Off 10min Recalibr...

Страница 16: ...ay Program 3 Edit Program Edit Program 1 Start Step 1 100 End Step 1 100 Edit Program Steps Step 1 Pan 0 255 Dimmer Fine 0 255 Step Time 0 25 5s Step 100 Pan 0 255 Dimmer Fine 0 255 Step Time 0 25 5s...

Страница 17: ...to move back to the previous screen menu up arrow used to move up on the previous page down arrow used to move down on the next page confirm used to save adjusted values to leave menu or to perform d...

Страница 18: ...rtnet MaNet Fixture receives Artnet protocol or MANet every fixture has to be connected to the Ethernet network Ethernet To DMX Fixture receives Artnet protocol from the Ethernet input and sends DMX d...

Страница 19: ...ture head since the counter was last reset In order to reset this counter to 0 touch the text box next to the item Maximum Res Driver Temperature The menu shows temperature of the plasma source driver...

Страница 20: ...rors Frost Errors Dimmer 2 Errors Cyan Errors Colour Errors Magenta Errors Gobo Errors Yellow Errors Gobo Carousel Errors CTO Errors Static Gobo Errors Clean Air Filters Iris Errors Overheated Focus E...

Страница 21: ...bles to close light output while the pan tilt coordinates are changing Colour Wheel Moving The menu item enables to close light output while the colour wheel is moving Gobo Wheel Moving The menu item...

Страница 22: ...ons on the wall ceiling or ground without any pan tilt move ment Adjust the pan tilt zoom focus and hot spot to desired positions an start test sequences by touching the green icon Music Trigger Use t...

Страница 23: ...from small to large Figure of triangle from small to large Figure of star from small to large Figure of cross from small to large DMX 0 1 127 128 129 130 255 Pan Tilt Macro Speed No macro generation...

Страница 24: ...n the menu Personality will be set to their default factory values To update software in the fixture I Installation of the DMX Software Uploader 1 DMX Software Uploader program is available from the R...

Страница 25: ...ing can be temporarily overwritten by the DMX value at the channel Power Special functions ranges of 30 39 DMX and 40 49 DMX Note because the plasma source comes up from 20 of its nominal power to the...

Страница 26: ...uit malfunctions sen sor failed or magnet is missing or the stepping motor is defective or its driving IC on the PCB The yoke is not located in the default position after the reset of the fixture Colo...

Страница 27: ...sage informs you that the lamp is too warm General Failure The message informs you that the internal failure was sensed as temp sensor failure 28V Failure The message informs you that the lamp was shu...

Страница 28: ...e setting and addressing Gravitation sensor for auto screen positioning Battery backup of the touch screen Readout fixture and lamp usage receiving DMX values temperatures etc Built in analyzer for ea...

Страница 29: ...recommended under no circumstances should alcohol or solvents be used DANGER Disconnect from the mains before starting any maintenance work The front objective lens will require weekly cleaning as smo...

Страница 30: ...wer if Shutter strobe channel 0 DMX step 50 59 Pan Tilt speed mode step 60 69 Pan Tilt time mode step 70 79 Blackout while pan tilt moving step 80 89 Disabled blackout while pan tilt moving step 90 99...

Страница 31: ...random colour selection from fast to slow proportional 8 Colour wheel fine positioning 0 255 Fine positioning proportional 9 8 6 Cyan 0 255 Cyan 0 white 255 full cyan proportional 10 9 7 Magenta 0 25...

Страница 32: ...of Rot Gobo Selection from max to min 0 25 5sec proportional 15 14 12 Static gobo wheel Continual Positioning In range 0 64 DMX is possible fine gobo positioning set value on channel 16 0 Open hole pr...

Страница 33: ...ex set indexing on channel 18 16 14 0 3 Open hole step 4 7 Gobo 1 step 8 11 Gobo 2 step 12 15 Gobo 3 step 16 19 Gobo 4 step 20 23 Gobo 5 step 24 27 Gobo 6 step 28 31 Gobo 7 step Rotation set rotation...

Страница 34: ...bo indexing rotation fine 0 255 Fine indexing rotation proportional 20 17 15 Prism 0 19 Open position hole step 20 127 3 facet rotating prism step 128 255 Prism gobo macros 128 135 Macro 1 step 136 14...

Страница 35: ...proportional 29 23 21 Shutter strobe 0 Shutter closed lamp power redused to 20 of nomin power step 1 31 Shutter closed full lamp power step 32 63 Shutter open full lamp power step 64 95 Strobe effect...

Отзывы: