7.2 Tab "Information"
Fixture Times
- The menu provides readouts of fixture and lamp operation hours.
Power On Time Hours
- Select this menu to read the number of fixture operation hours.
Total Hours
-.
The item shows the total number of the operation hours since the
Robin 300 Plasma Spot has been fabricated.
Resetable Hours
.-.
The item shows the number of the operation hours that the
Robin 300 Plasma Spot has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Lamp On Time Hours
- Select this menu to read the number of the operation hours with the lamp on.
.
.
Total Hours
-.
The item shows the total number of the operation hours with the lamp
on since the Robin 300 Plasma Spot has been fabricated.
.
.
Resetable Hours
.-
The item shows the number of the operation hours with the lamp
on that the Robin 300 Plasma Spot has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Lamp Strikes
- Select this menu to read the number of lamp strikes.
Total Strikes
- The item shows the total number of the lamp strikes since the
Robin 300 Plasma Spot has been fabricated.
.
.
Resetable Strikes
- The item shows the number of the lamp strikes since the counter was
last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Strikes:"
.
.
.
Fixture Temperatures
- The menu is used to view temperatures of the fixture´s inside.
...
Head Temperature
- The menu shows temperatures in the fixture head near the reflector.
.
.
Current
- A current temperature of the fixture head.
Maximum NonRes.
- A maximum temperature of the fixture head since the fixture has
been fabricated.
.
.
Maximum Res.
- A maximum temperature of the fixture head since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
.
.
.
.
.
Driver Temperature
- The menu shows temperature of the plasma source driver in the fixture head.
.
.
Current
- A current temperature of the driver.
Maximum NonRes.
- A maximum temperature of the driver since the fixture has
been fabricated.
.
.
Maximum Res.
- A maximum temperature of the driver since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
...
Base Temperature
- The menu shows temperature in the fixture base (on the display PCB).
.
.
Current
- A current temperature in the fixture base.
Maximum NonRes.
- A maximum temperature in the fixture base since the fixture has
been fabricated.
.
.
Maximum Res.
- A maximum temperature in the fixture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Air Filters
- Regular cleaning of the air filters is very important for the fixture´s life and performance.
Bild-up of dust, dirt and fog fluid residues reduces the fixture´s light output and cooling ability.
The two items of this menu help you to keep cleaning period of the air filters.
.
.
Alert period
- Cleaning schedule for the fixture depends on the operating environment.
It is therefore impossible to specify accurate cleaning interval. This item allows
you to change the cleaning interval of the air filters. This "alert" value is 300 hours and it
is set as default. Inspect the fixture within its 300 hours of operation to see whether cleaning
is necessary. If cleaning is required, clean all air filters and change the value in this menu
on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time
- The item allows you to read the time which remains to cleaning air filters.
The time period is set in the menu mentioned above.
Expired time period is signalled by a negative mark (-) at the time value and a warning icon
Содержание Robin 300 plasma spot
Страница 1: ...Version1 6...