4.6 Ethernet connection
The fixtures on a data link are connected to the Ethernet with ArtNet communication protocol.The control soft
-
ware running on your PC (or light console) has to support Art-Net protocol.
Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP.Its purpose is to allow
transfer of large amounts of DMX 512 data over a wide area using standard network technology.
IP address
is the Internet protocol address.The IP uniquely identifies any node (fixture) on a network.
The Universe
is a single DMX 512 frame of 512 channels.
The Robin 300 Spot is equipped with 8-pin RJ- 45 socket for Ethernet input.Use a network cable category 5
(with four “twisted” wire pairs) and standard RJ-45 plugs in order to connect the fixture to the network.
RJ-45 socket (front view):
. .
RJ-45 plug (front view):
1- TD+
5- Not connected
.
.
.
.
-.TD-. .
.
6-.RX-
3- RX+
7- Not connected
4- Not connected
8- Not connected
Patch cables that connect fixtures to the hubs or LAN sockets are wired 1:1,that is,pins with the same numbers
are connected together:
.
-.
-.
3-3.
-.
5-5.
6-6.
-.
8-8.
.
If only the fixture and the computer are to be interconnected,no hubs or other active components are needed.
A cross-cable has to be used:
.
-3.
-6.
3-.
-8.
5-.
6-.
-5.
8-
If the fixture is connected with active Ethernet socket (e.g. switch) the network icon
will appear at the
bottom right corner of the screen:
Direct Ethernet operation
Connect the Ethernet inputs of all fixtures with the Ethernet network.
Option “ Artnet/MaNet” has to be selected from “Ethernet Mode” menu on the fixture.
Set IP address (002.xxx.xxx.xxx / 010.xxx.xxx.xxx) and the Universe.
(DMX address=129)
(DMX address=33)
(DMX address=1)
IP addres=002.168.002.004
IP addres=002.168.002.003
IP addres=002.168.002.002
Universe=1
Universe=1
Universe=1
An advised PC setting: IP address: 002.xxx.xxx.xxx / 010.xxx.xxx.xxx (Different from fixture IP addresses)
NET mask: 255.0.0.0