9 Trouble-shooting
▸ Wash on a 40 °C wash programme to
clean off heavier deposits.
2
Inserting the cooler filter
The cooler filter does not have to be dry before being inserted in the filter case.
▸ Put the cooler filter
2
into the filter
case
1
. Ensure it is positioned correctly
(see cut-out in diagram).
▸ Insert the filter case
1
.
The filter case can only be pushed completely in if it is in the correct position.
8.10
Cleaning the drum illumination
▸ If necessary, wipe carefully with a soft cloth.
9
Trouble-shooting
9.1
Error messages
You may be able to trouble-shoot the following malfunctions yourself. If not, note down
the error message in full (message, F and E numbers) and call Customer Services.
Display
Possible cause
Solution
A0 Check outlet
▪
The drain hose is
blocked, kinked or de-
fective.
▪
The pumping height of
the drain hose is too
high (>1.2 m).
▪
The appliance is con-
nected to a concealed
double drain trap.
▸ Check part of drain hose
that is not housed in appli-
ance.
▸ Remove the cause of the
problem.
▸ Acknowledge the message
by touching the button.
▸ Start a programme.
If the error appears again:
▸ Note down the message in
full and the serial number
(SN).
▸ Disconnect the power sup-
ply to the appliance.
▸ Contact Customer Services.