Electrical connection

Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.

A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.

The appliance is designed for use up to a max. altitude of 2000 m above sea level.

Refer to the identification plate for information on the required mains voltage, current type and fuse protection.

The appliance is equipped with a connection cable which must be connected to an on-site junction box.

Installation pipe

Distribution box

Clamp

brown + black

blue

yellow/green

black

blue

yellow/green

brown

GK27TIYSZ - EU

black

black

yellow/green

GK17TIYSZ - EU + CN

N

L1

PE/

220–240 V~

1 1 

1 1 

1 1 1 1

2 2 2 2 2 2 2 2

brown

blue

yellow/green

N

L1

PE/

220–240 V~

GK27TIYSZ - CN

L2

L1

N

N

L1

PE/

PE/

380–415 V 2N~

220–240 V~

Error message U400

Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.

Quickly disconnect the appliance from the mains!

Ventilation

In order to guarantee good ventilation, a space of ≥10 mm
height is necessary beneath the appliance.

1.

The rear panel of the base unit must be open around the
work surface cut-out to guarantee continuous air circula-
tion via the ventilation slits.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.

2.

Alternatively, a concealed fresh air supply can ensure air
circulation inside the cabinet.
In order that enough cold air can be drawn in, there must
be a continuous circulation of fresh air that extends outside
the cabinet.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.

≥15

2

1

Содержание GK17TIYSZ

Страница 1: ...ral notes If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed Identification plate The identification pla...

Страница 2: ...no Steel angle set hob size 40 Steel angle set hob size 60 H63771 H63772 Ventilation protective plate set for niche width 550 mm Ventilation protective plate set for niche width 600 mm H61082 H61083...

Страница 3: ...ltage current type and fuse protection The appliance is equipped with a connection cable which must be connected to an on site junction box Installation pipe Distribution box Clamp brown black blue ye...

Страница 4: ...under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the underside of the hob ventilation opening Ri Corner radii...

Страница 5: ...mm A Worktop depth in combination with directly built under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the un...

Страница 6: ...e Well fitting seal over width of cabinet element Air gap over entire width of cabinet element 17 cm According to template Fan Drawer Type X Remarks GK17TIYSZ GK27TIYSZ 14 3 mm Surface mounted install...

Страница 7: ...e under the corresponding menu item is displayed above the first active slide to the left of the button Use the first active slider to the left of the button to change the values The left half of the...

Отзывы: