manualshive.com logo in svg
background image

Installation instructions

Built-in variants
Teppan Yaki
GK17TIYSZ, GK27TIYSZ

1014839-R03

21/11/2017

1014839-R03

5

Flush installation

The cooking zone layout of the hob to be fitted may differ from the hob illustrated!

600

≥3

00

600/

50

0

507±1

 ≥41.5

 ≥41

. 5

A

On both sides 
for technical reasons

577±

1

Z

Steel angle bonded

or screw mounted

C

D

Ra

R0–5

8.5

8.5

8.5±0.5

8.5±0.5

 0

-1

 0

-0.5

Detail Z

Ri

50

1

57

1

GK27TIYSZ

Y

Y

H

X

X

 ≥41.

5

600

60

0/550

507±1

 ≥41.5

≥300

≥400

390±1

Z

On both sides 
for technical reasons

384

501

Ri

GK17TIYSZ

Y

Y

H

H

≥10 

*

 

Y – Y

B

Drawer/Cabinet

Side panel

B

H

≥10 

*

 

X – X

For 550 niche,
for GK27TIYSZ

* The required clearance must be observed!

Type

A Depends on producer

B

H

Corner radius Ra/Ri

C/D

GK17TIYSZ

≥30 mm

≥73.6 mm

64 mm

5/1.5 mm

373/490 mm

GK27TIYSZ

560/490 mm

A

Worktop depth (in combination with directly built-under oven; does not apply to small appliances)

B

Required clearance for service replacement

H

Dimension from the top of the work surface to the underside of the hob (ventilation opening)

Ri

Corner radii of appliance

Ra

Outer corner radii of cut-out

Installation

Create an accurate installation cut-out.

The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Ac-
cessories).

Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the appliance
base can be removed from below.

Prepare the cut-out and appliance according to the specifications in the enclosed cementing-in instructions and align the appliance
in the cut-out.

Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.

Connect to the electrical mains connection before inserting the appliance, if necessary.

Содержание GK17TIYSZ

Страница 1: ...ral notes If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed Identification plate The identification pla...

Страница 2: ...no Steel angle set hob size 40 Steel angle set hob size 60 H63771 H63772 Ventilation protective plate set for niche width 550 mm Ventilation protective plate set for niche width 600 mm H61082 H61083...

Страница 3: ...ltage current type and fuse protection The appliance is equipped with a connection cable which must be connected to an on site junction box Installation pipe Distribution box Clamp brown black blue ye...

Страница 4: ...under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the underside of the hob ventilation opening Ri Corner radii...

Страница 5: ...mm A Worktop depth in combination with directly built under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the un...

Страница 6: ...e Well fitting seal over width of cabinet element Air gap over entire width of cabinet element 17 cm According to template Fan Drawer Type X Remarks GK17TIYSZ GK27TIYSZ 14 3 mm Surface mounted install...

Страница 7: ...e under the corresponding menu item is displayed above the first active slide to the left of the button Use the first active slider to the left of the button to change the values The left half of the...

Отзывы: