Surface-mounted installation

The cooking zone layout of the hob to be fitted may differ from the hob illustrated!

600

≥3

00

600/

50

0

490±1

 ≥50

 ≥50

A

On both sides 
for technical reasons

560±

1

Ra

 ≥50

600

60

0/550

490±1

 ≥50

≥300

≥400

373

±1

384

501

Ra

Ri

GK17TIYSZ

Y

Y

H

On both sides 
for technical reasons

Ri

50

1

57

1

GK27TIYSZ

Y

Y

H

H

≥10 

*

 

Y – Y

B

Drawer/Cabinet

Side panel

* The required clearance must be observed!

Type

A Depends on producer

B

H

Corner radius Ra/Ri

GK17TIYSZ, GK27TIYSZ

≥30 mm

≥77.6 mm

64 mm

0–5/1.5 mm

A

Worktop depth (in combination with directly built-under oven; does not apply to small appliances)

B

Required clearance for service replacement

H

Dimension from the top of the work surface to the underside of the hob (ventilation opening)

Ri

Corner radii of appliance

Ra

Outer corner radii of cut-out

Installation

Do not damage the sealing bead.
The sealing bead must lie all around the edge of worktop.

Create an accurate installation cut-out.

Carefully put the appliance in the installation cut-out and press against the worktop with sufficient overlap.

Combination installation

For surface-mounted combination installation, the side strip set 1028587 and the intermediate support 1014361 (stainless steel) or
1019199 (black) is needed.

The side strips must be fixed on the left-hand and right-hand side of the appliance with four screws on each side.

Surface-mounted combination installation is described in document 1013773.

Содержание GK17TIYSZ

Страница 1: ...ral notes If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed Identification plate The identification pla...

Страница 2: ...no Steel angle set hob size 40 Steel angle set hob size 60 H63771 H63772 Ventilation protective plate set for niche width 550 mm Ventilation protective plate set for niche width 600 mm H61082 H61083...

Страница 3: ...ltage current type and fuse protection The appliance is equipped with a connection cable which must be connected to an on site junction box Installation pipe Distribution box Clamp brown black blue ye...

Страница 4: ...under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the underside of the hob ventilation opening Ri Corner radii...

Страница 5: ...mm A Worktop depth in combination with directly built under oven does not apply to small appliances B Required clearance for service replacement H Dimension from the top of the work surface to the un...

Страница 6: ...e Well fitting seal over width of cabinet element Air gap over entire width of cabinet element 17 cm According to template Fan Drawer Type X Remarks GK17TIYSZ GK27TIYSZ 14 3 mm Surface mounted install...

Страница 7: ...e under the corresponding menu item is displayed above the first active slide to the left of the button Use the first active slider to the left of the button to change the values The left half of the...

Отзывы: