Installation instructions
Built-in variants of gas hob
Multi-sliders GAS411/421
1009436-R07
22/02/2018
1009436-R07
8
Cancelling user settings
▸
Press the button.
–
Any changes made to the default values are not saved.
–
The «Service menu» mode is ended.
Conversion to another gas type
The appliance is set up for a certain gas type, which is also recorded on the identification plate. The appliance can be converted to an-
other type of gas using the nozzle set supplied (others available as accessories). To this end, the injector nozzles in the burner must be
changed and the corresponding gas type must be selected from the service menu.
All the nozzles are numbered to avoid any possibility of confusion.
Always disconnect the appliance from the electricity and gas mains before changing the nozzles.
Changing the injector nozzles
▸
Remove the pan supports and burners.
▸
It is also necessary to remove the nozzle cover flap if the hob has a wok burner.
▸
Remove central injector nozzles (using 7 mm socket wrench).
Town gas nozzles: With a flat object e.g. screw driver.
▸
Remove horizontal injector nozzles in the wok burner using an open-end wrench.
Town gas nozzles: First unscrew the sleeve from the nozzle.
▸
Screw in the new injector nozzles (according to the table) as far as they will go.
Town gas nozzles for wok: Screw sleeves, if any, over external thread of the nozzles.
▸
It is necessary to put back the nozzle cover flap if the hob has a wok burner.
▸
Put back the burners and pan supports.
▸
Reconnect the appliance to the electricity and gas mains.
Changing the gas characteristics
▸
Access the service menu (see previous section).
▸
Select the desired gas characteristics under item
and save.
For the appliance, the following gas types are available:
Gas type
Test gas
Connection
pressure
Setting in the
menu
Injector nozzles (ø in hundredths of a mm)
Standard
burner
Rapid
burner
Wok burner
Inside
Outside
China natural gas
12T
20 mbar
104
143
71
2 × 125
China liquid gas
20Y
28 mbar
74
104
46
2 × 80
Affixing the gas sticker
After conversion to another gas type, the sticker supplied with the nozzle set must be affixed in the appropriate place on the identifica-
tion plate.
The appliance must be tested for leak tightness before using for the first time.