V-ZUG GAS411 Series Скачать руководство пользователя страница 6

Installation instructions

Built-in variants of gas hob
Multi-sliders GAS411/421

1009436-R07

22/02/2018

1009436-R07

6

Minimum distances and installation conditions

The distance from the appliance cut-out to the back wall must be ≥50 mm and to the side walls ≥200 mm. Parts such
as side walls and reinforcing strips which protrude into the installation space under the cooking zone must be made
of fire-resistant material.
The distance between the underside of the appliance tray and any part of the cabinet beneath that is made of com-
bustible material must be ≥20 mm.

≥750

≥450

When a range hood is installed above the gas hob, the minimum distance given for
the particular range hood must be observed.
Furthermore, the minimum distances illustrated must be strictly complied with if a
lower value is stated for the range hood.

The worktop must be flat in order that it is sufficiently sealed against the ingress of
liquids.

In order to guarantee good ventilation, a space of at least 20 mm in height is ne-
cessary beneath the appliance.

The appliances are designed for use up to a max. altitude of 2000 m above sea
level.

Gas connection

The gas connection and the conversion to another gas type must be carried out by an authorized installer.

67

187

32.5

G½ ISO 228/1

65

67

187

GAS411

GAS421

The gas connection must be positioned so that the stop-cock and the supply connection point are accessible with the appliance in-
stalled.

The gas connection must be positioned so that it does not get detrimentally hot during operation. In particular, the gas hose assem-
blies and the appliance’s connection fittings must be clear of hot exhaust gases (e.g. from an oven).

It must be ensured that the gas hose and the mains connection do not touch any hot parts of the appliance, otherwise the gas hose
and the mains cable could become damaged through heat.

A flexible connection lead (max. length 1.5 m) must be positioned so that it runs freely and does not come into contact with any mov-
able parts of the kitchen cabinets (e.g. a drawer).

No external pressure reducer is required if the connection pressure corresponds to the details on the identification plate.

Gas type

Test gas

Connection pressure

Remarks

China natural gas

12T

20 mbar

No external pressure reducer is required.

China liquid gas

20Y

28 mbar

½-inch metric thread

The gas connection on the appliance has a ½-inch external thread in accordance with ISO 228/1. If the gas installation on site already
has a corresponding counterpart, the gas appliance can be directly connected to it.

It is imperative to use the sealing ring for the front-end seal!

Содержание GAS411 Series

Страница 1: ...icular attention must be paid to the relevant ventilation requirements If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be...

Страница 2: ...of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 40 H63771 Designation Article no Instant adhesive for installation of steel angle Permabond F246 incl activa...

Страница 3: ...de of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between...

Страница 4: ...urfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installation Create an accurate installation cut out The mounting surface can be reamed out or created by insta...

Страница 5: ...ent type and fuse protection The connection cable has either a plug or three stranded wires Plug in appliances must be connected to an easily accessible power socket Appliances with stranded wires mus...

Страница 6: ...be carried out by an authorized installer 67 187 32 5 G ISO 228 1 65 67 187 GAS411 GAS421 The gas connection must be positioned so that the stop cock and the supply connection point are accessible wi...

Страница 7: ...appliance has already been connected for a longer period interrupt the power supply for about 10 seconds With the hob switched off hold the and buttons depressed at the same time for 4 seconds An aco...

Страница 8: ...zles With a flat object e g screw driver Remove horizontal injector nozzles in the wok burner using an open end wrench Town gas nozzles First unscrew the sleeve from the nozzle Screw in the new inject...

Отзывы: