Installation instructions

Built-in variants of gas hob
Multi-sliders GAS411/421

1009436-R07

22/02/2018

1009436-R07

4

Flush installation

The layout of the hob to be fitted may differ from the hob illustrated!

600

 ≥40

0

≥41.5

≥41.

5

507±1

60

0

A

Z

390±1

GAS411GSBZ, GAS421GSBZ

H

384

501

Ri

Y

Y

H

Y – Y

B

A

S*

 ≥85

T

 ≥90

Drawer/
cabinet

Side panel

Ra

8.5

 0

-1

8.5

 0

-0.5

8.5

 0/+1

8.5

 0/+1

Detail Z

C

D

R0–5

Steel angle bonded

or screw mounted

* The required clearance must be observed!

Type

A Depends on producer

B

H

Corner radius Ra/Ri

C/D

GAS411GSBZ, GAS421GSBZ

≥30 mm

≥175 mm

98 mm

5/1.5 mm

373/490 mm

A

Worktop depth

B

Required clearance for service replacement

H

Dimension from the top of the work surface to the underside of the gas connection

Ri

Corner radii of appliance for base plate

Ra

Outer corner radii of cut-out

S

Minimum distance between the top of the work surfaces and any drawer

T

Minimum distance between the cut-out in the back and any drawer

Installation

Create an accurate installation cut-out.

The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Ac-
cessories).

Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the appliance
base can be removed from below.

Prepare the cut-out and appliance according to the specifications in the enclosed cementing-in instructions and align the appliance
in the cut-out.

Fit the four adjusting braces along the circumference of the appliance to the bore holes provided and tension the appliance against
the worktop.

Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.

Connect to the electrical mains connection before inserting the appliance, if necessary.

Combination installation

Flush-mounted combination installation is described in document 1014381. The intermediate support kit H63789 is required for this.

Содержание GAS411 Series

Страница 1: ...icular attention must be paid to the relevant ventilation requirements If installing into a combustible material the guidelines and standards for low voltage installations and fire protection must be...

Страница 2: ...of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 40 H63771 Designation Article no Instant adhesive for installation of steel angle Permabond F246 incl activa...

Страница 3: ...de of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between...

Страница 4: ...urfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installation Create an accurate installation cut out The mounting surface can be reamed out or created by insta...

Страница 5: ...ent type and fuse protection The connection cable has either a plug or three stranded wires Plug in appliances must be connected to an easily accessible power socket Appliances with stranded wires mus...

Страница 6: ...be carried out by an authorized installer 67 187 32 5 G ISO 228 1 65 67 187 GAS411 GAS421 The gas connection must be positioned so that the stop cock and the supply connection point are accessible wi...

Страница 7: ...appliance has already been connected for a longer period interrupt the power supply for about 10 seconds With the hob switched off hold the and buttons depressed at the same time for 4 seconds An aco...

Страница 8: ...zles With a flat object e g screw driver Remove horizontal injector nozzles in the wok burner using an open end wrench Town gas nozzles First unscrew the sleeve from the nozzle Screw in the new inject...