manualshive.com logo in svg
background image

Installation instructions

Heat pump dryer
Multi-family building

J173.113-0

6.4.11  ITH

1

 

These installation instructions apply to the model: 

173

The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order 
specified.

Validity

Transport

The appliance is only to be transported in the upright position! Transporting it in any other position will result in damage to the 
appliance! When carried carefully, without being shaken, the appliance may be tilted to the left by a maximum of 90° (viewed 
from the front).
The appliance must be allowed to stand in the standard operating position for about 2 hours before using the heat pump. Failure 
to observe this can result in damage to the appliance.

Front

Front

Front

Back

Front,

upside down

Side

Use a stairclimber
to avoid knocks! 

Содержание 173

Страница 1: ...is only to be transported in the upright position Transporting it in any other position will result in damage to the appliance When carried carefully without being shaken the appliance may be tilted to the left by a maximum of 90 viewed from the front The appliance must be allowed to stand in the standard operating position for about 2 hours before using the heat pump Failure to observe this can r...

Страница 2: ...om between consecutive drying programmes If the volume of the room in which the appliance is located is 40 m There must be air inlet and outlet openings open window ventilation grille or slits in the door ventilation system to the adjacent room or to the outside Identification plate Installation accessories supplied Designation Article no Pieces See installation step Condensate drain kit W5 1346 1...

Страница 3: ...is plate fixes the appliance in position The minimum distances to walls and distances to adjacent appliances must be observed see table Use the floor attachment set article no 81 1311 32 for an uneven or sloping floor In such instances the installation plate cannot be used The heat pump dryer can only be combined with a washer dryer tower if the minimum room height and side access for cleaning are...

Страница 4: ...ly level the dryer using the rear adjustable feet Set the adjustable feet using counter nuts 2 Place the dryer on the installation plate D and push it as far as it will go 3 Level the front adjuster feet until the dryer is standing firmly on the floor The dryer must not wobble 4 To ensure smooth fault free operation the dryer must be perfectly vertical Use a spirit level E to position the dryer 5 ...

Страница 5: ...anies A plug in appliance may only be connected to a socket outlet with earthing contact installed according to specifications An all pole mains isolating device with 3 mm contact opening should be provided in the house wiring system Switches plug and socket devices circuit breakers and fusible cut outs which are accessible after installation and which have all poles switching are permissible as i...

Страница 6: ...ut automatically after 30 minutes or after the following actions Open the appliance or press the button Interrupting the function test The function test can be interrupted in 2 ways 1 Open the appliance door In the display appears After closing the appliance door appears in the display Or 2 Press the button In the display appears Aborting the function test In the display appears Press the button I...

Отзывы: