Installation instructions

Heat pump dryer
Multi-family building

J173.113-0

6.4.11  ITH

6

When the appliance is connected to the power supply for the first time, it is possible to select a function test. The purpose of the function 
test is to check the installation and it lasts about 3 minutes. For the function test, it is not necessary for the appliance to have been 
standing in the normal operating position for approx. 2 hours, as the heat pump is not started. The function test can therefore be selected 
immediately after installation.

Starting the function test

Connect the appliance.

– In the display 

 appears and the indicator lights for the buttons 

 and 

 flash.

Press the 

 button.

– The function test starts and 

 appears in the display.

Completing the function test

– On completion of the function test 

 appears in the display.

– The display goes out automatically after 30 minutes or after the following actions:

Open the appliance

or

press the 

 button.

Interrupting the function test:

The function test can be interrupted in 2 ways:

1. Open the appliance door.

– In the display 

 appears.

– After closing the appliance door 

 appears in the display.

Or

2. Press the 

 button.

– In the display 

 appears.

Aborting the function test:

– In the display 

 appears.

Press the 

 button.

– In the display 

 appears.

4. Using for the first time

The function test cannot be aborted by power outage.

Once the function test has been run, it can no longer be selected and the appliance enters the normal selection mode.

The appliance is only ready to operate after the required waiting time of approx. 2 hours in the normal operating 
position

. Failure to observe this can result in damage to the appliance.

Function test pause

next

abort

Function test

0h03

Function test

complete

Function test pause

Close appliance door

Function test pause

next

abort

Function test pause

next

abort

Function test pause

next

abort

Function test

complete

Содержание 173

Страница 1: ...is only to be transported in the upright position Transporting it in any other position will result in damage to the appliance When carried carefully without being shaken the appliance may be tilted to the left by a maximum of 90 viewed from the front The appliance must be allowed to stand in the standard operating position for about 2 hours before using the heat pump Failure to observe this can r...

Страница 2: ...om between consecutive drying programmes If the volume of the room in which the appliance is located is 40 m There must be air inlet and outlet openings open window ventilation grille or slits in the door ventilation system to the adjacent room or to the outside Identification plate Installation accessories supplied Designation Article no Pieces See installation step Condensate drain kit W5 1346 1...

Страница 3: ...is plate fixes the appliance in position The minimum distances to walls and distances to adjacent appliances must be observed see table Use the floor attachment set article no 81 1311 32 for an uneven or sloping floor In such instances the installation plate cannot be used The heat pump dryer can only be combined with a washer dryer tower if the minimum room height and side access for cleaning are...

Страница 4: ...ly level the dryer using the rear adjustable feet Set the adjustable feet using counter nuts 2 Place the dryer on the installation plate D and push it as far as it will go 3 Level the front adjuster feet until the dryer is standing firmly on the floor The dryer must not wobble 4 To ensure smooth fault free operation the dryer must be perfectly vertical Use a spirit level E to position the dryer 5 ...

Страница 5: ...anies A plug in appliance may only be connected to a socket outlet with earthing contact installed according to specifications An all pole mains isolating device with 3 mm contact opening should be provided in the house wiring system Switches plug and socket devices circuit breakers and fusible cut outs which are accessible after installation and which have all poles switching are permissible as i...

Страница 6: ...ut automatically after 30 minutes or after the following actions Open the appliance or press the button Interrupting the function test The function test can be interrupted in 2 ways 1 Open the appliance door In the display appears After closing the appliance door appears in the display Or 2 Press the button In the display appears Aborting the function test In the display appears Press the button I...

Отзывы: