Installation instructions

Heat pump dryer
Multi-family building

J173.113-0

6.4.11  ITH

3

1. Remove the transport packaging.

2. Raise the appliance on one side and pull out one half of the installation plate.

3. Raise the appliance on the other side and pull out the other half of the installation plate.

4. Fit the two halves of the installation plate together and place in the desired position (observe 

minimum distances, see table). If there are plumbing fittings behind the appliance or if the 
surrounding walls are not perpendicular, these distances must be adjusted accordingly.

5. Affix the installation plate to the floor using the double-sided adhesive tape supplied. The 

installation plate can also be screwed to the floor.

Washer-dryer tower

Minimum distances

Installation

Work steps 

1

5

 must be carried out in full in the order specified.

1. Positioning the installation plate

Use the installation plate to install the appliance. This plate fixes the appliance in position.

The minimum distances to walls and distances to adjacent appliances must be observed (see table).

Use the floor attachment set (article no. 81.1311.32) for an uneven or sloping floor. 
In such instances, the installation plate cannot be used.

The heat pump dryer can only be combined with a washer-dryer tower if the 

minimum room height

 

and 

side access

 for cleaning are ensured.

Installation is not possible in a closed niche!

1. Raise the dryer on one side and pull out one half of the installation plate.

2. Raise the dryer on the other side and pull out the other half of the 

installation plate.

3. Fit the two halves of the installation plate together and affix the 

installation plate to the clean and dry cover plate using the double-sided 
adhesive tape supplied. Press down firmly (see picture for alignment).

If you want to screw down the installation plate, use screws no 
longer than 12 mm.

Minimum distance

A

B

C

Single appliance

10 mm

250 mm

Washer-dryer tower

600 mm

250 mm

Appliances positioned side by side

10 mm

250 mm

10 mm

min. 1950 mm

Room height

65,5

B

A

B

A

C

Washing

machine

Tumble

dryer

Содержание 173

Страница 1: ...is only to be transported in the upright position Transporting it in any other position will result in damage to the appliance When carried carefully without being shaken the appliance may be tilted to the left by a maximum of 90 viewed from the front The appliance must be allowed to stand in the standard operating position for about 2 hours before using the heat pump Failure to observe this can r...

Страница 2: ...om between consecutive drying programmes If the volume of the room in which the appliance is located is 40 m There must be air inlet and outlet openings open window ventilation grille or slits in the door ventilation system to the adjacent room or to the outside Identification plate Installation accessories supplied Designation Article no Pieces See installation step Condensate drain kit W5 1346 1...

Страница 3: ...is plate fixes the appliance in position The minimum distances to walls and distances to adjacent appliances must be observed see table Use the floor attachment set article no 81 1311 32 for an uneven or sloping floor In such instances the installation plate cannot be used The heat pump dryer can only be combined with a washer dryer tower if the minimum room height and side access for cleaning are...

Страница 4: ...ly level the dryer using the rear adjustable feet Set the adjustable feet using counter nuts 2 Place the dryer on the installation plate D and push it as far as it will go 3 Level the front adjuster feet until the dryer is standing firmly on the floor The dryer must not wobble 4 To ensure smooth fault free operation the dryer must be perfectly vertical Use a spirit level E to position the dryer 5 ...

Страница 5: ...anies A plug in appliance may only be connected to a socket outlet with earthing contact installed according to specifications An all pole mains isolating device with 3 mm contact opening should be provided in the house wiring system Switches plug and socket devices circuit breakers and fusible cut outs which are accessible after installation and which have all poles switching are permissible as i...

Страница 6: ...ut automatically after 30 minutes or after the following actions Open the appliance or press the button Interrupting the function test The function test can be interrupted in 2 ways 1 Open the appliance door In the display appears After closing the appliance door appears in the display Or 2 Press the button In the display appears Aborting the function test In the display appears Press the button I...

Отзывы: