background image

2

GLOSSARY

In the present list they are rechon up the terminologies and abbreviation descriptions most 

commonly used on the present manual.

H.P
L.P
min.
max.
1’
h
H
L
Fig.
Pag.
Sez.
Automat.
Man.

High pressure
Low pressure
Minimum
Maximum
Minutes
hour
Height
Length
Figure
Page
Section
Automatically
Manual

Rif.
V
Ah
Hz
kW

˚

C

kg
CO
l/h
Mono
Tri
TS
CEE

Reference
Volt
Ampere
Hertz
Kilowatt
Degrees centigrade
Kilogram
Carbon dioxide
Litres/hour
Monophase
Triphase
Total Stop
European Economic Community

LEGENDA

FLUXOSTATH

Device suitable for take off the flux of a liquid

SUMMARY

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

INTRODUCTION
GENERAL DIRECTIONS
IMPORTANT RECOMMENDATIONS
TECHNICAL FEATURES
TECHNICAL DATAS
DIMENSIONS
MACHINE DESCRIPTION
IDENTIFICATION DATA
CONTROLS
ADHESIVES
OUTFIT
SAFETY STANDARDS
IMPROPER USE
WRONG USE
PRECAUTIONS
INSTALLATION
USE
MAINTENANCE
FAULT-CAUSE-REMEDIES
SYSTEM PLANS

Pag.  1
Pag.  1
Pag.  2
Pag.  3
Pag.  4
Pag.  5
Pag.  5
Pag.  6
Pag.  7
Pag.  7
Pag.  7
Pag.  8
Pag.  8
Pag.  8
Pag.  10
Pag.  11
Pag.  11
Pag.  13
Pag.  15
Pag.  16

21

22
23
24
25

TRANSPORT-HOISTING
DISPLACEMENT
STORING
WARRANTY CONDITIONS
ACCESSORIES
SCRAPPING

Pag.  17

Pag.  17
Pag.  18
Pag.  19
Pag.  20

Содержание RAPIDHB240-21

Страница 1: ...RAPIDHB240 21 RAPIDHB110 21 Please read this manual before using the HB240 21 HB110 21 V TUF RAPID HOT BOX...

Страница 2: ...Community LEGENDA FLUXOSTATH Device suitable for take off the flux of a liquid SUMMARY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 INTRODUCTION GENERAL DIRECTIONS IMPORTANT RECOMMENDATIONS TECH...

Страница 3: ...conductivity upper lower head and vane in stainless steel bottom made of thich refractary cement embedded in the casing Quick coupling assembled on the water inlet and outlet Two rigid type rubber whe...

Страница 4: ...200 bar 450 W 900 l h 4 bar 30 150 53 000 K cal h 230 V monophase 70 kg 11 litres less than 2 on the Shell Bacharach scale les than 0 04 of the volume 50 Hz ACOUSTIC PRESSURE LEVEL IN ATMOSPHERE ACOUS...

Страница 5: ...5...

Страница 6: ...0000 0000 0000 0000 0000 0000 0000 0000 0000 Feeding Cable Water Inlet Water Outlet Rigid rubber wheels Pivotant wheels Pivotant wheels with parking brake Handle Parking brake Control panel Frame Cov...

Страница 7: ...You think that is necessary to protect it do it letting the air through so as to cool down the motor Switch the machine off during longer idle periods more than 15 20 minutes and unload the pressure i...

Страница 8: ...le or things The machine should be placed out of passage ways and in order to avoid mechanical stress and damages CHECKS BEFORE USE Before the use check that all the parts was fitted up and that the i...

Страница 9: ...000030 We suggest the use of a chimney as illustrated in the picture WARNING the chimney 2 diameter Z should not be inferior than the adapter 1 USE IN WINDY PLACE In case the machine is placed in a wi...

Страница 10: ...zle size 07 Pressure 50 BAR Nozzle size 065 Pressure 60 BAR Nozzle size 06 Pressure 70 BAR Nozzle size 05 Pressure 100 BAR Nozzle size 04 Pressure 145 BAR Remember Please select the best jet spray ang...

Страница 11: ...revious page Picture 1 2 Please the jet into the end of the spray lance and then check your calibration on cold Once you are happy with this then turn the thermostat of your HOTBOX on highest temperat...

Страница 12: ...ic Using compressed air for clean or dry parts of the machine protect the eyes with goggles equipped with side guards and limit the air working pressure at max 1 9 bar Every day keep clean and in good...

Страница 13: ...ng aromatic solvents methanol or hydrocarbon HYDRAULIC SYSTEM Periodically check that all the system parts are correctly tights and that are not leakages COIL If the coil is covered with sooth You sho...

Страница 14: ...aintenance Service Completely drain the gasoil tank than fill up with clean gasoil Turn the adjusting screw until obtaining aprox 10 bar contact the Maintenance Service Adjust the distance between the...

Страница 15: ...14 SYSTEM PLANS WIRING DIAGRAM I MP TA F E V T M Switch Burner motor Transformator Fluxostath Gasoil solenoid valve Thermostat Ground...

Страница 16: ...fore informations descriptions and illustrations contained in this publication are updated until their approval for the printing WARNING the graphic illustration of the part can be different from the...

Страница 17: ...16...

Отзывы: