13
BURNER MAINTENANCE
The burner installed on our high pressure cleaner, runs only with gasoil.
Periodically check and clean the filters and the fuel nozzle, we
recommend the replacement of the same every 400 working hours.
BODY AND TANK WORK MAINTENANCE
Wash the machine only with neutral surface-active products and water in order to eliminate
corrosive agents (such as salt, sand, etc.); accurately dry so as to thoroughly eliminate
any patches of water.
If trace of dirt persist, we recommend the use of specific products following the instructions
provided by the manufacturer.
WARNING:
DO NOT USE products containing aromatic solvents, methanol
or hydrocarbon.
HYDRAULIC SYSTEM
Periodically check that all the system parts are correctly tights
and that are not leakages.
COIL
If the coil is covered with sooth, You should check the burner at the
Customer Service Centre.
AIR FLOW ADJUSTMENT
On 60 Hz models is installed an air flow adjusting blade; this
device placed between the fan and the boiler is adjusted by
the manufacturer but acting on the apposite nut, the slope
will be changed for allow a small or a greater air flow.
ELECTRODES SETTING
To obtain the best performances of the machine, check that the starting electrodes are
always placed as showns in picture.
WARNING:
for repair, special maintenance operations or for setting up of the
machine, apply to the Customer Service Centre or to the authorized technicians
only.