V-tech DT601/FP Скачать руководство пользователя страница 2

Side View

Mounting box

Fingerprint

window

Rainy Cover

DT601/FP

93 mm

182 mm

30 mm

DT601F/FP

220 mm

120 mm

Camera Lens
Speaker

Call Button
Microphone

Night Light 

Screws for panel 

mounting

Camera Lens
Speaker

LED 2
Call Button

Microphone

Night Light 

LED 1

KEY 2

KEY 1

LED 2

LED 1

KEY 2

KEY 1

Fingerprint

window

1.Parts and Functions

2.Terminal Descriptions

1  2  3

Lock Control Jumper

BUS PL

S+ S-

Main Connect Port

-1-

Содержание DT601/FP

Страница 1: ...DT601 FP DT601F FP English User Manual 2 Wire Video Outdoor Station DT ENG 601 F FP V1 141023...

Страница 2: ...Camera Lens Speaker Call Button Microphone Night Light Screws for panel mounting Camera Lens Speaker LED 2 Call Button Microphone Night Light LED 1 KEY 2 KEY 1 LED 2 LED 1 KEY 2 KEY 1 Fingerprint wind...

Страница 3: ...DT601 FP Mounting 2 Lock Control Jumper To select the lock type Main Connect Port To connect the bus line and the electronic locks BUS Connect to the bus line no polarity PL External lock power input...

Страница 4: ...mounting box and attach to the wall Attach the panel to the mounting box and use screws supplied to fix the panel Connect the cable correctly 4 System Wiring and Electric Lock Connection 4 1 Basic Con...

Страница 5: ...of Monitor must be set to 0 by default EB LOCK BUS PL S S Jumper position in 2 3 1 2 3 LOCK Take off the Jumper POWER SUPPLY BUS PL S S 4 2 2 Door Lock Controlled with Dry Contact Note 1 The external...

Страница 6: ...S IM BUS DS PC6 AC Note 1 must connect DT601 F FP correctly before setting 2 the parameter will be saved in DT601 F FP automatically so you need only set on one monitor 3 Here we take DT47M the monito...

Страница 7: ...6 4 5 1 Basic IN OUT Wiring Mode 4 5 Multi Monitors Connection Device Address 0 BUS IM BUS DS PC6 AC 100 240VAC Code 14 Code 15 Code 0 NOTE Here we take DT47M the monitor for example...

Страница 8: ...ice Address 0 Code 0 OFF ON OFF ON DBC4A A B C D DBC4A A B C D Impedance switch Impedance switch NOTE Here we take DT47M the monitor for example 100 240VAC BUS IM BUS DS PC6 AC Code 2 Code 1 Code 3 Co...

Страница 9: ...f The ID of doorstation can be set to ID0 ID1 ID2 ID3 The default is ID0 Followed by pressing the KEY2 button each time you press KEY2 to replace the ID Note The ID will cycle between ID0 ID1 ID2 ID3...

Страница 10: ...me press and hold KEY2 button timing starts release KEY2 button to end the timing The time of press and hold KEY2 button equal to unlock time Timing Unit 1s LED 1 Buzzer beep once per second green fla...

Страница 11: ...ree ringtone modes A one ringtone B continuous ringtone C forbid ringtone The default is one ringtone Followed by pressing the KEY2 button each time you press KEY2 to replace the ringtone mode Note Th...

Страница 12: ...in the fingerprint window get on the first time identified LED 1 LED 2 Buzzer beep beep green flash 3 times off Success blue LED 1 LED 2 Buzzer beep beep beep red flash 3 times off Failure off Touch...

Страница 13: ...Touch new Management Fingerprint get on the first time identified LED 1 LED 2 Buzzer beep beep green flash 3 times off Success blue LED 1 LED 2 Buzzer beep beep beep red flash 3 times off Failure off...

Страница 14: ...D 2 Buzzer beep beep beep red flash 3 times Failure off Note 1 In the second identified regardless of success or failure the system will return to the operation of first identified you can continue to...

Страница 15: ...eep green flash 3 times Success off LED 1 LED 2 Buzzer beep beep beep red flash 3 times Failure off Press KEY2 button It will enter the state of delete specified user fingerprints setting LED 1 LED 2...

Страница 16: ...mes Failure off Press and hold KEY1 and KEY2 button at the same time It will enter the state of delete all user fingerprints setting LED 1 LED 2 Buzzer beep beep off double flash on double flash Note...

Страница 17: ...ith the unit You must use the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a tra...

Страница 18: ...he DT system Using different cables may also affect the maximum distance which the system can reach When Monitor quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 Twisted cable 2x1 mm2 8...

Страница 19: ...18...

Страница 20: ...The design and specifications can be modified without notice to the user Right to interpret and copyright of this manual are reserved DT ENG 601 F FP V1 141023...

Отзывы: