![UWE SAC Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/uwe/sac-series/sac-series_operation-manual_1066093012.webp)
5.11.3 Clear Unit Piece Weight PLU
a.
Press
0
b.
Press and hold the preferred PLU location to clear
c.
Wait until the scale displays
PRE._SET
on
UNIT WEIGHT
PANEL
d.
Release PLU
e.
Memory is cleared and scale returns to normal
operation
5.12 COMPUTER DATA RS232C OUTPUT (OPTIONAL)
5.12.1 Connect the Scale with a Computer
Follow the below steps to connect the scale with a
computer.
a.
Turn scale off
b.
Turn computer off
c.
Connect the RS232C output of scale to computer with
an appropriate data cable
d.
Turn s cale on
e.
Turn computer on
f.
Load and run the BASICA program file (For DOS
platform)
5.12.2 Default Output Settings
•
BAUD RATE = 9600
•
DATA BITS = 8
•
PARITY = NONE
•
STOP BITS = 1
5.12.3 When Using DOS System
a.
Create BASICA computer program file as below to
enable the computer to receive data sent by scale.
10
OPEN "COM
*
:9600, N,8,1,CS,DS,CD" AS#1
*
: Input 1 if the input port of computer is
COM 1, or input 2 for COM 2 ...etc.
20
LINE INPUT #1, A$
30 PRINT A$
40 GOTO 20
50
END
b. Save the above program file.
5.13 PRINTER OUTPUT (OPTION)
By pressing the
M+
and by erasing the accumulated data
(by pressing
MR
followed by
CLEAR
), the follow data will
be transmitted to printer.
S/N
WT
@WT
PSC
(
NOTE 1
)
01.
78
1.0000
78
02.
580
2.0000
290
(
NOTE 2
)
03.
+++
100
(
NOTE 3
)
03/
658
468
(
NOTE 4
)
NOTE 1
:
S/N = Serial Number, WT = Weight, @WT= Unit Piece Weight,