c.
Enter preset weight value through numeric keys
d.
Value entered is shown on the
UNIT WEIGHT PANEL
e.
Press
@WT/SET
to confirm
f.
Scales displays
CH._Wt
on the
UNIT WEIGHT PANEL
while
the value entered on the
WEIGHT PANEL
g.
Scale return to normal operation within 2 seconds
5.10.3 Clear Quantity Check Limit
a.
Press
CHECK
b.
Press
0
c.
Press
NUMBER SET
d.
Wait until the scale return to normal operation
e.
The upper weight limit is now erased from memory
5.10.4 Clear Weight Check Limit
a.
Press
CHECK
b.
Press
0
c.
Press
@WT/SET
d.
Wait until the scale return to normal operation
e.
The upper count limit is now erased from memory
5.11 UNIT PIECE WEIGHT MEMORY (PLU)
5.11.1 Saving a Unit Piece Weight to PLU
This scale is equipped with 8 unit piece weight PLU
memories. Save a unit piece weight to PLU by either one
of the following methods:
a.
By
Direct entry method
, or
b.
By
Current unit piece weight method
5.11.a Direct Entry Method
a.
Key in the unit piece weight through keypad. Make
sure the unit piece weight does not exceed 6 figures
disregard the decimal place
b.
Press and hole the preferred PLU location for about
2 seconds unti l
Pr._SET
appears
c.
Data is now stored
5.11.b Current Unit Piece Weight Method
a.
Obtain a unit piece weight through procedures listed
on
5.5.b
b.
Press and hole the preferred PLU location for about
2 seconds until
Pr._SET
appears
c.
Data is now stored
NOTE
: Data stored in PLU will not be erased when scale
is powered off.
5.11.2 Recall Unit Piece Weight from Memory
To recall unit piece weight stored in memory, simply
press the corresponding PLU.
After the PLU is pressed, the unit piece weight will
be displayed on the
UNIT WEIGHT PANEL
.