Uvitron International INTELLI-RAY 600 Instruction Manual, Rev. T
Page 16 of 36
SYSTEM OPERATION (CONTINUED)
6
Fig. 5C, IntelliRay Setup Menu Map
(continued from previous page)
ENTR
MENU
Press ENTR
To Exit Setup
S13*
S14
MENU
ENTR
Set Password
(0 – 9999): ****
Confirm
Password: ****
ENTR/MENU
KEY:
BLUE
= Key Press,
= Menu Item #
XX
ENTR
S8
S10
MENU
MENU
Temp Unit: Deg F
ENTR to Toggle
Temp Unit: Deg C
ENTR to Toggle
ENTR
MENU
Time Unit: Secs
ENTR to Toggle
Time Unit: Hours
ENTR to Toggle
S11
MENU
MENU
Setup Menu (cont’d)
From Setup Menu
Interlock item S7
on page 15
To Main menu
Exposure Time item
M5 on page 14
To Setup Menu
Password Entry
menu item S1
on page 15
ENTR
S12
MENU
MENU
ENTR/MENU
Reset Lamp Hours
(0 – 9999H): 200
Overwrite Hours?
ENTR=Y, MENU=N
MENU=N
Lamp Hours Alarm
(0 – 9999H): 9999
MENU
S9
Oven Ovrtmp Alrm
(0 – 110C): 76
* Note: If a password is set, a Dose Lock
menu item will be next displayed to
optionally allow lock-out of time and
intensity settings (see S13 of section 6.6).