Uvitron International INTELLI-RAY 600 Instruction Manual, Rev. T
Page 21 of 36
SYSTEM OPERATION (CONTINUED)
6
S11
Lamp Hours Alarm Setting
The value set in this menu item will determine the number of elapsed operating hours at which
an alarm will be triggered to notify the operator to replace the currently installed arc lamp. The
value is adjustable because some applications are more sensitive than others with respect to
allowable lamp intensity decay before curing or exposure level is no longer acceptable. If a
value of zero hours is entered, the lamp hours alarm will be disabled.
S12
Reset Lamp Hours
From this screen, the lamp age timer can be reset after replacing an arc lamp. When the screen
is first entered, the current lamp age will be displayed. If a new lamp is installed, then a value of
zero should be entered for Lamp Hours. If a previously used lamp is installed, then the current
age of the lamp should be entered. After entering the new value, the operator will be prompted
to confirm overwriting of the current hours (to insure the current value isn’t changed
inadvertently). If the age of the lamp had exceeded the lamp hours alarm setting in Setup Menu
S11 (resulting in the Alarm light being activated), the alarm light will turn off when a new age of
less than the current lamp hours alarm setting is entered.
S13A
Set Password
This screen is used to enable or change the Setup Security Password. When the system is
delivered from the factory, the password is disabled by default, allowing all operators access to
the setup menu. To enable the password, enter a value from 0 to 9999. Once entered, the new
password must be confirmed by entering it a second time. If the two passwords do not match,
then an error message will be displayed, and the operator will be prompted to press “ENTR to
Retry”. If the passwords match, then the operator will be prompted to “Press ENTR to Exit
Setup”.
NOTE:
Care should be taken not to lose or forget the Setup password. If the password is
lost, contact the Uvitron customer support department to obtain a temporary password.
To disable the setup password, press ENTR for the new password, and ENTR for the
confirmation password. Th
is will prevent the “Enter Password” prompt from being displayed
when the Setup Menu is entered.
S13B
Dose Lock
If a password was entered, then the next menu item displayed will be a dose lock screen for
preventing unauthorized changes to Main Menu exposure time and intensity. The lock can be
toggled ON/OFF by pressing ENTR. When enabled, a Dose Locked message will be displayed
for time or intensity change attempts. The lock will be auto-disabled if the password is removed.
S14
Exit Setup
Exit Setup is the last screen of the Setup Menu. To exit the Setup Menu and return to the Cure
Menu, press the ENTR key. To go back to the top of the Setup Menu, press the MENU key.