Hallett 15xs Instruction Manual
Released on 11-Jul-13 – H800003Q
Page 37
UV Pure Technologies Inc. © 2013
screwdriver (counterclockwise while looking at the shaft).
MOTOR
MOTOR
PURGE VALVE
PURGE VALVE
THERMISTOR
THERMISTOR
WIRES
CUT WIRE TIE WRAP
WHEN NECESSARY
REMOVE & SUPPORT
TOP QUARTZ
SEAL ASSEMBLY
DISCONNECT 1/4"
PURGE VALVE DRAIN
REMOVE WIPER ASSY. BY
ROTATING IT COUNTER-
CLOCKWISE AS YOU LIFT
DISCONNECT
FLEX. HOSE
Figure 4C
Step 8:
Drain the unit and inspect the quartz sleeve. If clean, flush the unit with
clean water. If fouling remains, repeat procedure.
Step 9:
Once the unit is clean, reassemble the unit including the motor and top
hose connection.
Step 10:
Slowly open the water supply and check for leaks.
Step 11:
Replace all covers and plug in the Hallett unit.
Disassembling the Unit
NOTE: This procedure is not recommended for individual household users
please contact your certified water specialist to assist should disassembly be
required.
Step 1:
Fill a bucket or container with water before shutting off the water supply
since you will need the water later to clean the quartz sleeve (11). A squeeze
bottle is useful for applying water or cleaning solution
to the inside of the quartz
sleeve.
Step 2:
Place another bucket under the unit and drain the unit (see Draining the
Unit).
Step 3:
Open the front panel. The lamps may be removed to prevent them from
getting dirty or damaged.
Step 4:
Disconnect the Stainless flexible hose (8) from the top of the unit
and
remove the top quartz seal assembly.
Caution:
Do not damage the sealing surfaces of the end caps (5 and 19) or the