2NM/2NX/2NY/2NZ/2P0/2P6
1-5-60
34. Remove all connectors and FFCs from
the control PWB.
35. Remove six screws and control PWB
from the main unit.
Figure 1-5-101
36. Pull the connector out and then release
the wires from Hooks.
37. Remove three screws and then remove
the eject unit.
38. Check or replace the ejection unit and
refit all the removed parts.
Figure 1-5-102
Screw
Control PWB
Screw
Screw
Screw
Screw
Screw
Connector
Exit unit
Screw
Connector
Hooks
Wire
Screws