(2-5) U010XX error code table: G3 transmission
Error code
Description
U01000
An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001
Function of the unit differs from that indicated by a DIS signal.
U01010
No relevant signal was received after transmission of a DNL (MPS or EOM) signal, and
the preset number of command retransfers was exceeded (between units of our make).
U01011
No relevant signal was received after transmission of a DCS, TCF signal, and the preset
number of command retransfers was exceeded.
U01012
No relevant signal was received after transmission of an NSS1, NSS2 (TCF) signal, and
the preset number of command retransfers was exceeded (between units of our make).
U01013
No relevant signal was received after transmission of an NSS3, TCF signal, and the pre-
set number of command retransfers was exceeded (between units of our make).
U01014
No relevant signal was received after transmission of an MPS signal, and the preset
number of command retransfers was exceeded.
U01015
No relevant signal was received after transmission of an EOM signal, and the preset
number of command retransfers was exceeded.
U01016
An MCF signal was received but no DIS signal was received after transmission of an
EOM signal, and T1 timeout was detected.
U01017
No relevant signal was received after transmission of an EOP signal, and the preset
number of command retransfers was exceeded.
U01018
No relevant signal was received after transmission of a PRI-EOP signal, and the preset
number of command retransfers was exceeded.
U01019
No relevant signal was received after transmission of a CNC signal, and the preset num-
ber of command retransfers was exceeded (between units of our make).
U01020
No relevant signal was received after transmission of a CTC signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01021
No relevant signal was received after transmission of an EOR.Q signal, and the preset
number of command retransfers was exceeded (ECM).
U01022
No relevant signal was received after transmission of an RR signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01023
No relevant signal was received after transmission of a PSS.NULL signal, and the preset
number of command retransfers was exceeded (ECM).
U01024
No relevant signal was received after transmission of a PSS.MPS signal, and the preset
number of command retransfers was exceeded (ECM).
U01025
No relevant signal was received after transmission of a PPS.EOM signal, and the preset
number of command retransfers was exceeded (ECM).
U01026
No relevant signal was received after transmission of a PPS.EOP signal, and the preset
number of command retransfers was exceeded (ECM).
U01027
No relevant signal was received after transmission of a PPS.PRI-EOP signal, and the
preset number of command retransfers was exceeded (ECM).
U01028
T5 time-out was detected during ECM transmission (ECM).
Содержание P-4030 MFP
Страница 7: ...This page is intentionally left blank ...
Страница 13: ...This page is intentionally left blank ...
Страница 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Страница 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Страница 347: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 61 Figure 1 5 103 Exit unit Screw Screws Connector Hooks Wire 40 ppm model ...
Страница 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Страница 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Страница 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...
Страница 488: ... For Legal Folio OficioII 1 1 1 1 2 2 2 2 ...