2NM/2NX/2NY/2NZ/2P0/2P6
1-4-100
(9)
Registration clutch
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
Registration clutch and connect right PWB (YC12)
Connect right PWB and control PWB (YC29)
2. Defective clutch.
Replace the registration clutch.
3. Defective connect
right PWB.
Replace the connect right PWB (see page 2-2-36).
4. Defective PWB.
Replace the control PWB and check for correct operation
(see page 2-2-12).
(10)
Duplex clutch does
not operate.
(50/60 ppm model
only)
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
Duplex clutch and connect right PWB (YC12)
Connect right PWB and control PWB (YC29)
2. Defective clutch.
Replace the duplex clutch.
3. Defective connect
right PWB.
Replace the connect right PWB (see page 2-2-36).
4. Defective PWB.
Replace the control PWB and check for correct operation
(see page 2-2-12).
(11)
Developer clutch
does not operate.
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
Developer clutch and connect right PWB (YC12)
Connect right PWB and control PWB (YC29)
2. Defective clutch.
Replace the developer clutch.
3. Defective connect
right PWB.
Replace the connect right PWB (see page 2-2-36).
4. Defective PWB.
Replace the control PWB and check for correct operation
(see page 2-2-12).
(12)
Middle clutch does
not operate.
(50/60 ppm model
only)
1. Defective connector
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
Middle clutch and connect right PWB (YC12)
Connect right PWB and control PWB (YC29)
2. Defective clutch.
Replace the middle clutch.
3. Defective connect
right PWB.
Replace the connect right PWB (see page 2-2-36).
4. Defective PWB.
Replace the control PWB and check for correct operation
(see page 2-2-12).
Problem
Causes
Check procedures/corrective measures
Содержание P-4030 MFP
Страница 7: ...This page is intentionally left blank ...
Страница 13: ...This page is intentionally left blank ...
Страница 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Страница 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Страница 347: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 61 Figure 1 5 103 Exit unit Screw Screws Connector Hooks Wire 40 ppm model ...
Страница 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Страница 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Страница 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...
Страница 488: ... For Legal Folio OficioII 1 1 1 1 2 2 2 2 ...