Visit us online at www.USWaterSystems.com Give us a call at: 1-800-608-8792
15
GreenWave Water Conditioning System
Greenwave Carbon Tank and GreenWave Module Installation
1. Make sure the GreenWave Carbon tank is on a level surface. Make sure the bypass valve is in the bypass
position.
2. Install the inlet plumbing from the sediment filter outlet. The GreenWave carbon tank inlet is marked
“Downflow Inlet”.
3. Now install the GreenWave Tank outlet to the GreenWave module inlet. The GreenWave outlet is marked
“Upflow Inlet”. Plumb from this port to the inlet port on the GreenWave module. The GreenWave module has
an arrow on the housing showing direction of flow. The arrow points away from the inlet.
4. Be sure to snug the brass fittings on the GreenWave module. They are sealed with a rubber gasket and do
not require Teflon tape. All other threaded connections will require Teflon tape.