13. Shut off the water again and relieve the pressure at a faucet or spigot.
14. Once the pressure is relieved, use the supplied wrench to remove the GreenWave module
sump and install the GreenWave cartridge back into the sump. Be sure the O-ring is in place
and lubricated with food grade silicon grease or corn or vegetable oil.
NOTE:
DO NOT use petroleum based grease!
15. Install the GreenWave module sump and tighten it hand tight. Then turn it an additional 1/4 turn
to snug it further.
16. Open a faucet or spigot down stream and slowly turn on the water supply.
17. Allow the GreenWave module to fill with water then check it for leaks.
18. If there are no leaks, run the water unit it is clear then shut off the faucet or spigot.
19. The system is now operational. Be sure to check for leaks one final time.
Start Up