Softener Preparation
Fusion NLT Tank Installation Instructions
WATER PRESSURE:
A minimum of 20 pounds of water pressure is required for regeneration valve
to operate effectively.
ELECTRICAL FACILITIES:
An uninterrupted alternating current (A/C) supply is required. Note: Other
voltages are available. Please make sure your voltage supply is compatible with your unit before installation.
EXISTING PLUMBING:
Condition of existing plumbing should be free from lime and iron buildup.
Piping that is built up heavily with lime and/or iron should be replaced.
LOCATION OF FUSION NLT TANK AND DRAIN:
The Infusion tank should be located close to a drain
to prevent air breaks and back flow.
CAUTION:
Water pressure is not to exceed 80 psi, water temperature is not to exceed 110°F (43°C),
and the unit cannot be subjected to freezing conditions.
Media Installation
1) Remove the tank from carton.
2) Verify the riser tube is centered in the bottom center of the tank. A flashlight may be
necessary.
Содержание FNLT-100-HY
Страница 5: ...5 System Dimensions 15 Brine Tank 17 04 ...
Страница 22: ...22 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 Installation Instructions ...
Страница 25: ...25 Installation Overview ...
Страница 35: ...35 Main Repair Parts ...
Страница 38: ...38 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 Control Valve Parts List ...
Страница 39: ...39 Power Head Exploded View ...
Страница 40: ...40 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 Power Head Parts List ...
Страница 42: ...42 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 ...